ࡱ> _ Ԋbjbjzyzy G6b6b@|||||84`ef(@@@   ddddddd$f|i,e|e!  e!e!e||@@eW'W'W'e!*|@|@dW'e!dW'W'bY_c@EI"]Vd0e0`ei]j#j_cj|_cl 0K "W'm     ee1%&   `ee!e!e!e!j         B B: SECTION 10 22 19 demountable partitions GENERAL RELATED DOCUMENTS Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section. summary Section Includes: Modular partition framing Face tiles. Glass and glazing Doors and hardware. Accessories. Finishes. Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference. PREINSTALLATION MEETINGS Preinstallation Conference: Conduct conference at Project site. REFERENCE STANDARDS The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date. Reference amendments adopted prior to the effective date of this Contract shall be applicable to this Project. Materials, installation and workmanship shall comply with all applicable requirements and standards. definitions Demountable full height modular office partitions: A system of walls suitable for interior general office use. The basic components of the system are produced by a single manufacturer and are designed to permit relocation, reconfiguration and reuse of the components. Demountable full height high performance partitions: A system of walls suitable for interior special use applications which demand acoustical, air quality, thermal, and durability performance levels greater than that required for general office use. The basic components of the system are produced by a single manufacturer and are designed to permit relocation, reconfiguration and reuse of the components. Structural Panel System: A demountable partition system comprised of self supporting sandwich panel units which interlock by means of intermediate panel posts or other similar methods. Non Structural Panel System: A demountable partition system comprised of panels which are not self supporting and require a metal stud framework to be installed prior to panel application. SUBMITTALS Product Data: For each type of product. Shop Drawings: For demountable partitions. Include plans, elevations, sections, and attachment details at floors, columns, permanent partitions, and ceilings, and method of erection and disassembly. Include wiring diagrams for power, signal, and control wiring raceways, and details of access to raceways. Samples: For each exposed product and for each color and texture specified, [in manufacturer's standard sizes] [6 inches (150 mm) square in size] . Samples for Initial Selection: For each type of exposed finish. Include Samples of hardware and accessories involving color or finish selection. Samples for Verification: For each type of the following products: Face-Panel Finish: Manufacturer's standard-size unit, but not less than [6 inches (150 mm) square] . Linear Trim: [12-inch- (300-mm-)] long Samples. Retain "Door Finish" and "Glazing" subparagraphs below for doors and glazing if furnished by demountable-partition manufacturer. Door Finish: Manufacturer's standard-size unit, but not less than [3 inches (75 mm) square] . Glazing: Manufacturer's standard-size unit, but not less than [3 inches (75 mm) square] . Hardware and Accessories: [Whole units] . Coordination Drawings: Reflected ceiling plans and other details, drawn to scale, on which the following items are shown and coordinated with each other, using input from the installers of the items involved: Suspended-ceiling components and dimensioned ceiling-grid layout. Locations of fixed door and window mullions. Overhead bracing, seismic restraints, and related structural members. Ductwork above ceiling. Coordinate "Qualification Data" Paragraph below with qualification requirements in Section014000 "Quality Requirements" and as may be supplemented in "Quality Assurance" Article. Qualification Data: For Installer. Retain "Product Certificates" Paragraph below to require submittal of product certificates from manufacturers. Product Certificates: For each type of demountable partition. Product Test Reports: For each type of demountable-partition assembly, for tests performed by manufacturer and witnessed by a qualified testing agency. Maintenance Data: For demountable partitions to include in maintenance manuals. QUALITY ASSURANCE [DELETE OR REVISE 2 OPTIONS BELOW IF NOT REQUIRED BY SIZE OF JOB.] [ARCHITECT/ENGINEER MUST DELETE EVERYTHING IN BLUE AND IN BRACKETS BEFORE PUBLISHING.] Manufacturer Qualifications: Manufacturer shall specialize in designing and manufacturing modular partitions of the quality and complexity required for this project with a minimum 10 years documented successful experience. Manufacturer shall have production facilities capable of meeting contract requirements for single-source responsibilities and warranties. Installer Qualifications: Engage an experienced Installer who has successfully completed demountable partition installations similar in material, design, and extent to that indicated for Project and is certified by manufacturer. Single Source Responsibility: Obtain materials from one source from a single manufacturer. [REVISE OR DELETE CHARACTERISTIC BELOW IF NOT APPLICABLE. FIRE HAZARD RATINGS VARY WITH EACH MFR. AND TYPE OF MATERIAL.] [USE CAUTION, AND AVOID REFERENCE TO STANDARDS UNLESS YOU ARE VERY FAMILIAR WITH EACH ONE AND ARE AWARE OF ALL THEIR EMBEDDED OPTIONS. USE THIS ARTICLE TO INDICATE THE FULL DESIGNATION AND TITLE TO ELIMINATE HAVING TO REPEAT THEM IN PARTS 2 AND 3.] Fire Performance Characteristics: Provide a system of demountable partitions that is identical to that tested for the following fire performance requirements, according to test method indicated, by UL or other testing and inspecting agency acceptable to authorities having jurisdiction. Identify products with appropriate markings of applicable testing and inspecting organization. [REVISE FLAME SPREAD AS REQUIRED.] Surface Burning Characteristics: As follows: [CHOOSE FROM 2 OPTIONS BELOW.] Flame Spread: Not more than 25 Smoke Developed: Not more than 50 Flame Spread: Not more than 75 Smoke Developed: Not more than 100 [GENERALLY RETAIN TEST METHOD BELOW WHICH IS REFERENCED BY AUTHORITIES HAVING JURISDICTION. ALL REFER TO WHAT IS ESSENTIALLY THE SAME METHOD.] Test Method: ASTM E 84 Test Method: UL 723 Test Method: NFPA 255 [REVISE FIRE RATINGS BELOW AS REQUIRED.] One hour fire rated partition assembly: ASTM E 119 Twenty minute fire rated door assembly: ASTM E 152 Physical Properties: Provide demountable partitions that are identical to that tested for the following physical properties, according to the test method indicated. [REVISE ACOUSTICAL RATINGS AS REQUIRED.] Acoustical Characteristics: Provide system of demountable partitions that is identical to that tested in accordance with ASTM E 90 for an STC rating of 40. Load Bearing Characteristics: Provide a system of demountable partitions that is identical to that tested for the following load bearing properties, according to the test method indicated. [SELECT FROM 2 OPTIONS BELOW OR REVISE LOAD BEARING CHARACTERISTICS AS REQUIRED.] Test Method: BIFMA Proof Load Standard for Static Loads. Rating: 4.5 pounds per lineal inch. Test Method: BIFMA Proof Load Standard for Static Loads. Rating: 7 pounds per lineal inch. Certification: Submit manufacturer's certificate stating that materials furnished comply with specified requirements. Include supporting certified laboratory testing data indicating that material meets specified test requirements. Mock up for Verification Purposes: In a location designated by the Architect, install a full scale installation incorporating at least one of each type of panel, and accessory required, illustrating each installation condition. Retain mock up installation until completion of total installation or dismantle earlier at the direction of the Architect. Materials used for the mock up installation will not be considered part of either the base contract materials or the attic stock materials. DELIVERY, STORAGE and HANDLING Deliver materials to Project Site in original factory wrappings and containers, clearly labeled with identification of manufacturer, brand name, quality or grade, fire hazard classification, and lot number. Store materials in original undamaged packages and containers, inside well ventilated area protected from weather, moisture, soiling, extreme temperatures, and humidity; laid flat, blocked off ground to prevent sagging and warping. Comply with instructions and recommendations of manufacturer for special delivery, storage, and handling requirements. Extra materials Refer to Section 01 78 46 for Maintenance Material Requirements. sequencing and scheduling Sequence demountable partition installation with other Work to minimize possibility of damage and soiling during remainder of construction period. [IF ANY ALTERNATES, ALLOWANCES OR UNIT PRICES APPLY, ADD HERE.] WARRANTY Provide manufacturer's standard, limited, transferable warranty executed in the name of the Owner. Guarantee site assembled modular structure, panel system, and components are free from defects in material and workmanship. Warranty Period: 10 year limited warranty. PRODUCTS GENERAL Materials shall meet or exceed all applicable referenced standards, federal, state and local requirements, and conform to codes and ordinances of authorities having jurisdiction. manufacturers Basis of Design Manufacturer: DIRTT Environmental Solutions. Subject to compliance with requirements, manufacturers offering products which may be incorporated into the Work include, but are not limited to, the following: Knoll International. KI. Haworth. Steelcase. DIRTT Environmental Solutions. Teknion Corp. SYSTEM DESCRIPTION Factory assembled, site installed, moveable, demountable, reusable interior solid and glazed partitions, including structure, face mounted finished tiles, modular and non-modular metal framing and doors to accept a variety of millwork, finishes, building services components, technology, and accessories. System is floor-supported, floor-to-ceiling site constructed in configurations shown on the Shop Drawings. Top channels hold modular partitions in place and accommodate height adjustments to suit floor-to-ceiling dimensional variations and similar site specific requirements. Where modular partitions are not clipped to ceilings or other overhead construction, additional structural review and system engineering will be required by the manufacturer. Panel Attachment: Unitized aluminum frame assembly to support face mounted tiles in orientation and module increments as shown on the Drawings. Partially Unitized Solid Wall system shall be comprised of modular components which can be disassembled, relocated / field cut and substantially reused. Face tiled finishes applied to lightweight frame system, may be monolithic or segmented with the ability to span off-module, or across multiple frames in segments or monoliths, vertically and horizontally. Manufacturer shall provide integrated strategy for accommodating accessory channels and reveals integrated into the structural frame allowing universal horizontal alignment to support millwork, furniture, storage and accessories without defacing or damaging face tile or structural frame. Materials manufactured by others shall not exceed the modular partition manufacturers limitations or tested performance. Manufacturer shall provide accommodation / provision for the embedding of technology in the wall cavity: structural framing shall allow for universal non standard AV display, sound, and various support equipment to be mounted in the cavity of the wall with all required structural brackets, wire management, access and ventilation equipment to prevent overheating. Manufacturer shall provide ability for independent configuration / finish. Each side of wall must have the capability for variable aesthetic and function to suit different requirements. This will allow for the one side of the wall to have a totally independent function than the other to meet each organizations requirement. Manufacturer shall accommodate and provide provisions for additional embedded elements (ie sofas, exam tables, chaises, charting stations, and millwork) in the wall cavity as documented. Embedded elements and accessories to be provided by others may require additional engineering for structural framing and supports within modular partitions. Submit documentation of all items to be mounted to or embedded in modular partitions for manufacturer review and approval. Do not proceed with procurement or fabrication without modular partition manufacturers review and approval. Electrical and Communications Access: 1 inch (25 mm) to 3 inches (75 mm) clear wall cavity for accessible from either side of partition by removable face tiles. Provide back boxes, supports, and conduit as required to accommodate data, security and communications indicated on shop drawings. Modular partition manufacturer to provide continuous 1 inch (25 mm) open cavity vertically and horizontally between all frames. Modular partition manufacture shall allow for adaptability and retrofitting of hardware for future division of partitions, tiles, or supports to the greatest extent practical. MODULAR PARTITION FRAMING Framing for Solid and Face Tiled Partitions: Material: Aluminum extrusions, 6063T6 aluminum alloy, thickness engineered to meet performance requirements specified above. Vertical Support Spacing: 6 inch (150 mm) minimum to 48 inch (1219 mm) maximum. Ceiling Track: Continuous, with intermittent breaks for pass through of building services or structural components. Floor Track: Modular with wall frames inclusive of carpet grippers or floor tape (non-seismic) or continuous with floor anchor attachment (seismic) stopped at doorways and pass-throughs. Bracing: as required to meet structural performance. Fasteners: Zinc Plated Steel Type F Screws unless otherwise indicated on engineered shop drawings. Framing for Glazed Partitions: Same as solid panel framing with customized spacing as shown on the Drawings. Maximum spacing 60 inches (1524 mm). Frame Bases: Provide frame bases with provisions for 1-1/2 inch (38.1 mm) height adjustment to accommodate floor slab variances. Provide a leveling mechanism for making fine adjustment in height over adjustment range of the product. FACE MOUNTED FINISHED TILES Panel Construction: Standard Solid Tile Material: Medium Density Fiber Core (MDF). Thickness: Solid Tiles: 1/2 inch (13 mm). Glass Tiles: 1/4 inch (6 mm) with aluminum mounting rails to maintain alignment with adjacent finishes. Widths: As shown on shop drawings. Height: As shown on shop drawings. Finishes: As specified below and as shown on the Drawings. Reveals: Classic: 0.35 inch (9 mm); Enzo: 0.15 inch (4 mm). GLASS AND GLAZING Typical: Tempered glass minimum thickness 6 mm (1/4 inch) to ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type 1, Class 1 (transparent), Quality q3. Back Painted Glass: As specified with finishes below. Laminated Glass: To ASTM C1172, Kind LA fabricated from two nominal 3 mm (1/8 inch) pieces of Type 1, Class 1, Quality q3, flat annealed transparent glass conforming to ASTM C1036. Specialty Glass: To match the Architects Sample. Specialty glass materials must be approved by manufacturer prior to procurement or fabrication. DOORS AND DOOR HARDWARE General: Coordinate security system components to be provided by others with Modular partitions manufacturer through the Shop Drawing process. Provide uneven leaf doors as documented on Shop Drawings. Glazed Aluminum Doors: Manufacturer's standard stiles and rail door, [butt hinge] [pivot] [sliding] operation, glazed aluminum doors. Door Thickness: 1-15/32 inches (43 mm) thick. Stile Width: [2] [4] [6] inches ([51] [102] [152] mm). Top Rail Height: [4] [6] inches ([102] [152] mm). Bottom Rail Height: [7-7/8 inches (200 mm)] [12 inches (305 mm)] AFF. Provisions for ADA bottom rails as determined by the design professional of record. Adjustability: Provide door skirt to accommodate varying floor levels. Door Height: As noted on shop drawings. Maximum height 10 feet (3 meters). Glazing: [Tempered] [Laminated] glass, [6] [10] mm ([1/4] [3/8] inch) thick, [_____] custom finish. Hardware Reinforcement: Factory milled by modular partition manufacturer to suit glass and hardware supplied by others as shown on show drawings. Flush Wood Doors: Manufacturer's standard solid core door, [butt hinge] [pivot] [sliding] operation [and glazed]. Door Thickness: 1-15/32 inches (43 mm) thick. Pressed high density fibreboard on both sides of door on particleboard core. Edging: Solid edging. Stile Width for Glazed Door: 6-3/16 inch (157 mm). Door Height: [6'-8" (2032 mm)] [6'-10" (2083 mm)] [7'-0" (2134 mm)] [Maximum height 10 feet (3 meters)]. Glazing: [Tempered] [Laminated] glass, [1/4] [3/8] inch ([6] [10] mm) thick, [_____] custom finish. Finish: Manufacturers standard selected by Architect. Frameless Glass Pivot Door: Specified glass with top rail and bottom aluminum rails supplied locally by others. Door Glazing: 1/2 inch (13 mm) tempered glass (supplied locally by others). Stile Width: None. Top Rail Height: 2-5/16 inch (59 mm). Bottom Rail Height: 2-5/16 inch (59 mm). Provisions for ADA bottom rails as determined by the design professional of record. Hardware Reinforcement: Factory milled by modular partition manufacturer to suit glass and hardware supplied by others as shown on show drawings. Security System Components: Coordinate security system requirements and components to be provided by others with modular partitions manufacturer through the shop drawing process. Frameless Glass Sliding Door: Manufacturers supplied top rail and bottom aluminum rails (glass supplied locally by others). Door Glazing: 3/8 inch (10 mm) tempered glass supplied locally by others. Stile Width: None. Top Rail Height: 2-3/8 inch (61 mm). Bottom Rail: 5 inch (127mm) AFF. Provisions for ADA bottom rails as determined by the design professional of record. Hardware Reinforcement: Factory milled by modular partition manufacturer to suit glass and hardware supplied by others as shown on show drawings. Security System Components: Coordinate security system requirements and components to be provided by others with modular partitions manufacturer through the shop drawing process. DOOR FRAMES Pivot Door Frames: Manufacturer's standard aluminum frame [single door] [double door], reversible, factory milled to receive hardware, for 1-15/32 inches (43 mm) +/- 1/16inch (1.5mm) doors. Door Module Size: As scheduled. Finished door width is equal to module width less 2 inches (51 mm). Configuration: Header, jambs and pivot hardware. Single door frame width not to exceed 44 inch (1118 mm) wide module. Hardware Preparation and Reinforcement: Milled, reinforce, drill and tap frames at factory to receive specified hardware in accordance with the contract hardware schedule and templates. Frame Height: Jambs shipped over length (height) by 2 inches (51 mm), for field cutting to suit opening height for proper alignment with adjacent frames. Electrical Requirements: Security System Components: Coordinated hardware requirements and prep work for security system components (supplied by others including but not limited to: electronic strikes, Magnetic locks, electrified locksets, hinges, request to exit buttons, motion sensor rex, door position contacts). Factory notched and drilled jambs for ceiling track and manufacturers standard header attachment. Extrusion Profile: [Curvilinear] [Rectilinear] [_______] profile to match any adjacent unitized glass frames. Seals: Manufacturer's standard. Butt Hinge Frames: Manufacturer's standard aluminum frame [single door] [double door], factory milled to receive hardware, for 43 mm (111/16 inch) [+/ 1.5mm (1/16 inch)] doors. Door frames capable of reconfiguration without part replacement or damage to wall components. Door Module Size: As scheduled. Finished door width is equal to module width less 3 inches (76 mm). Configuration: Header, jambs and pivot hardware. Single door frame width not to exceed 51 inch (1219 mm) wide module. Hardware Reinforcement: milled, reinforce, drill and tap frames at factory to receive specified hardware in accordance with the contract hardware schedule and templates. Frame Height: Jambs over length 50 mm (2 inches), for field cutting to suit opening height for proper alignment with adjacent frames. Frame Preparation: Factory milled frame with hinge locations and sizes as determined and set by manufacturer; including factory installed steel backer plates for four (4) hinges (2 pair): Hinges: 4-1/2 x 4 Stanley BB1409 fastened with 10-24 flat head machine screws. For C.O.M. Doors Conform to modular partition manufacturer's standard size, hole pattern and fastener type for hinges, levers or pulls to be supplied by others. Electrical Requirements: Security System Components: Coordinated hardware requirements and prep work for security system components (supplied by others including but not limited to: electronic strikes, Magnetic locks, electrified locksets, hinges, request to exit buttons, motion sensor rex, door position contacts). Factory notched and drilled jambs for ceiling track and manufacturers standard header attachment. Extrusion Profile: Curvilinear profile to match any adjacent unitized glass frames. Seals: Manufacturer's standard. Sliding Door Frames: Manufacturer's standard aluminum frame [single door] [double door], single continuous track mounted to demountable wall system and capable of reconfiguration without part replacement or damage to wall components. Door Module Size: [_______.] [As scheduled.] Finished door width is equal to module width plus 1/4 inch (6 mm). Configuration: Header, jambs and pivot hardware. Single door frame width not to exceed 1524 mm (60 inch) wide module for Aluminum Doors and 1219mm (48inch) for Wood Doors. Self supporting header and track, jambs, sliding door, and trackless at floor between jambs. Frame Height: Jambs shipped over length by 50 mm (2 inches) in height, for field cutting to suit opening height for proper alignment with adjacent frames. Factory notched and drilled jambs for ceiling track and manufacturers standard header attachment. Extrusion Profile: [Curvilinear] [Rectilinear] profile to match any adjacent unitized glass frames. Frame and Track Construction: Continuous extruded frame supported or drywall header section with concealed track mechanism. Guide and alignment hardware for stabilization of door bottom. Door secured in closed position on strike side of door. Anti rack / lift hardware included in track assembly. Operation: Soft lose mechanism for door weights of 165 pounds (75 kg) or less. Pneumatic slow down mechanism for door weight of 165 to 200 pounds (75 to 90 kg). Seals: continuous acoustical seals on strike and guide side. Manufacturer's standard. Operation and configuration ADA compliant in both clear opening as determined by design professional of record. Hardware: As specified in Division 08 Door Hardware. ACCESSORIES Connections and Supports: Manufacturer's standard connections and supports that connect and release from floor and ceiling without damage using carpet grippers and ceiling track clips, with exception of the following conditions: bulkhead (drywall ceiling), seismic conditions, electrical or service feeds, physical connections to base building (where required). Panel Joint Closure: Manufacturer's standard, capable of closing up to a 25 mm (1 inch) gap between demountable partitions and base building elements. Trim: Continuous and modular, factory finished, snap on type; field cuttable for variations in floor and ceiling levels. Base Trim Profiles: Recessed; removable to access leveling mechanisms. Ceiling Trim Profile: Recessed; adjustable to accommodate up to a 12 mm (1/2 inch) gap between demountable partitions and base building elements. Wall Trim Profile: Recessed; adjustable to accommodate up to a 12 mm (1/2 inch) up to 25 mm (1 inch) gap between demountable partitions and base building elements. Tile to Tile Profile: As detailed. Colors: As selected by Architect from manufacturer's full range. Brackets: Manufacturer's brackets, supports and accessories for complete installation of system's furniture components, architectural millwork, audio visual equipment, and paper accessories. Provide bracket design to enable other system furniture to mount to modular partitions, on or off module. Infection Prevention Measures: Provide extrusions and co-extrusions to fill voids between tiles, at ceiling connections, and at base building connections as required. (both horizontal and vertical gaskets). Coordinate final locations of gaskets with manufacturer through the shop drawing process prior to procurement of fabrication. FABRICATION Modular Tiles: Unless otherwise inducated on shop drawings, factory assembled frames with 1inch (25 mm) insulation, base track and levellers; face mounted tiles installed to frames on site. Components: Fabricate components for installation with concealed fastening devices and pressurefit members that will not damage ceiling or floor coverings. Exceptions: Drywall ceiling, seismic applications and doors against base building require screw holes in base building for proper fastening. Fabricate for installation with manufacturers standard seals at floor and other locations where partition assemblies abut fixed construction and for installation of sound attenuation insulation in partition cavities. FINISHES Protect finishes on exposed surfaces from damage during shipping. Appearance of Finished Work: Finishes shall match approved samples. Variations in natural finishes such as stone and wood shall be reviewed and accepted in accordance with industry standards. Frame Finishes: Clear Anodized Aluminum: AAMA 611, AAM12C22A31, Class I. Powdercoat Color: Factory applied to match paint finish as follows: Series: [Standard.] [Paint match.] Color: [______]. Paint Match Manufacturer: [______]. Paint Match Description: [______]. Paint Match Color number: [______]. Wood Veneer Wrapped Finish (VEN): Factory applied wood veneer finish as follows: Series: Standard. Wood Veneer Species: [______]. Wood Veneer Cut: [______]. Stain Finish: [______]. Factory Applied Panel Finishes: Make joints only where total length exceeds maximum manufactured length. Joints and reveals as indicated on approved Shop Drawings. Paint Finish (PNT): Series: [Standard] [Paint match]. Coating Type: UV cured water based paint, Chromacoat or approved equivalent. Color: [______]. Paint Match Manufacturer: [______]. Paint Match Description: [______]. Paint Match Color number: [______]. Wood Veneer Finish (VEN): Series: Standard. Minimum Thickness: [_____]. Wood Veneer Species: [______]. Wood Veneer Cut: [______]. Stain Finish: [______]. Thermofoil Finish (THRM): Material: [______]. Profile: [______]. Color: [______]. Sheen: [______]. Texture: [______]. Solid Surface Finish (CRN): Material: Corian by DuPont or approved equivalent. Color: [______]. Upholstered Fabric Finish (FAB): Class A fire rated per ASTM E84 or other testing standard acceptable to the local building authority. Series: [As selected from the manufacturers standard line.] [COM.] Pattern: [______]. Color: [______]. Direction: [Standard.] [Railroaded.] Edges: [______]. Tackable Fabric Finish (TFAB): Class A fire rated per ASTM E84 or other testing standard acceptable to the local building authority. Series: [As selected from the manufacturers standard line.] [COM] Pattern: [______]. Color: [______]. Direction: [Standard.] [Railroaded.] Edges: [______]. Frameless Back Painted Glass: Standard Back Painted Glass (GLS): Series: [Standard.] [Paint match.] Paint Match Manufacturer: [______]. Paint Match Description: [______]. Paint Match Color number: [______]. Magnetic Back Painted Glass (MGLS): Series: [Standard.] [Paint match.] Color: [______]. Paint Match Manufacturer: [______]. Paint Match Description: [______]. Paint Match Color number: [______]. Laminated Glass (LGLS): center mount paint finish unless otherwise indicated. Series: [Standard.] [Paint match.] Coating Type: [______] Color: [______]. Paint Match Manufacturer: [______]. Paint Match Description: [______]. Paint Match Color number: [______]. Specialty Glass: (WGLS) Willow Glass by Corning or approved equivalent: WGLS_PNT: Willow glass back painted as specified above. WGLS_GRA: Willow glass with graphic treatment to match the Architects sample. [_______]. Write Away Tile (MCF): Series: [Standard.] [Paint match.] Color: [______]. Paint Match Manufacturer: [______]. Paint Match Description: [______]. Paint Match Color number: [______]. Magnetic Markerboard: Porcelain enamel, balanced, high-pressure laminated, porcelain enamel-faced tiles, of three ply construction consisting of face sheet, core material, and backing. Porcelain Face Sheet: Prefinished 28 gauge steel adhered to substrate. Core Material: 1/2 inch (13 mm) thick MDF. Color: White. Slat Wall (ANO): Series: [Anodized] [Powder coat paint match.] Color: [______]. Manufacturer: [______]. Description: [______]. Size: [6 inch (150 mm)] [_____]. Color Number: [______]. Door Finishes: [Clear anodized aluminum; AAMA 611, AAM12C22A31, Class I] [________]. Door Finish: As selected from manufacturers full range. EXECUTION [COORDINATE REQUIREMENTS SPECIFIED IN OTHER SECTIONS FOR CONSTRUCTION AND TOLERANCES TO ENSURE THAT THEY ARE APPROPRIATE FOR MATERIALS SELECTED.] PREPARATION Prior to installation of demountable partition system, clean floor to remove dust, debris, and loose particles. [DELETE IF PROJECT IS NOT RENOVATION.] Illuminate areas of installation to provide an ambient light level of at least 100 foot candles measured in the area where partitions are to be installed. Acclimatize materials by removing from sealed protective wrappings for a period of not less than 48 hours prior to installation. Provide protection from damage during this period. Verify that materials are those specified before installing. Maintain temperature in the area of installation at a constant minimum of 65 degrees F with relative humidity less than 70 percent for a period of 48 hours prior to installation and during installation process. INSTALLATION Installation shall meet or exceed all applicable federal, state and local requirements, referenced standards and conform to codes and ordinances of authorities having jurisdiction. All installation shall be in accordance with manufacturers published recommendations. Install demountable partitions and accessories after other finishing operations, including painting, have been completed. Do not use materials with defects which are visible in the finished Work. Install demountable partitions to comply with Drawings and final shop drawings in strict compliance with manufacturer's printed instructions. Install panel surfaces flat and with straight tight vertical and horizontal joints, with components assembled into a rigid structure, fitted to building conditions, straight and plumb with horizontal lines level. Conceal screws, nuts, and rivets. Replace damaged items with new materials. Install partitions on top of finished flooring. Where on carpeting, furnish snap on carpet adaptors which permit installation of partition system without damage to carpeting or other finished flooring. Install partitions after finished ceiling has been installed. [BELOW APPLIES TO STRUCTURAL PANEL SYSTEM ONLY.] Lock panel and door frame units together by alignment clips precision fit to panel posts. Conceal alignment clips and posts by continuous light and sound seal. Brace each post condition to ceiling with a rigid post extension which permits continuous wiring distribution within partition. [BELOW APPLIES TO NON STRUCTURAL PANEL SYSTEM ONLY.] Install partitions using concealed fastening devices which will not mar floor and ceiling surfaces. Provide through posts to ceiling or structure as shown on approved shop drawings and as required to assure lateral stability. [INSERT ADDITIONAL SIMILAR PARAGRAPHS FOR OTHER SPECIAL APPLICATIONS AS REQUIRED FOR PROJECT.] [REVISE QUANTITIES BELOW OR DELETE REQUIREMENT IF SIZE OF PROJECT DOES NOT WARRANT THIS ADDITIONAL WORK] FIELD QUALITY CONTROL Testing: Upon completion of installation, test partitions to demonstrate capability and compliance with requirements by removing and reinstalling three wall panels and three door and frame units selected by the Architect. END OF SECTION 10 22 19 FOR MDACC USE ONLY. DELETE THIS PAGE BEFORE ISSUING DOCUMENTS. document revision history IssueDateRevision DescriptionAuthor20190301Original IssuanceRev. 1.Rev. 2Rev. 3 Rev. 4 Rev. 5    MD ANDERSON Project No. XXXXXXMD Anderson PROJECT NAMEA/E Name Issue Description A/E Project No.Month 00, 0000 鶹ӳ demountable partitions MD Anderson Cancer Center10 22 19 MS 20190301 PAGE 20 of  NUMPAGES 20 '(AB}K L  ) * = > + 4 e h k¾}v}vv}v h;qhrE0h;qhrE05h;qhrE00J&5B*phh;qhrE00J'5B*phhrE0hrE05hrE0h1 hdI~h+}/hdI~h+}/ h+}/@ h;qhdI~ hdI~hh h@hhFYh'V hFJ@hFJ h;qhFJ h;qh1.(0B  ! 5 B L * > + Agd gd gd  `gd>gd)gd)VTF1wCf   `gddI~gd gd gd '1FT (/2CCf  NOPtuRSCDdļμμμθΏΏh1 h{Uha_hqha_hT>hQr` h{UhT> h{UhB_<hFJhrE0hrE05hrE0hrE00J&5hrE0h;qhrE00J&5B*phh;qhrE00J'5B*ph h;qhrE0h;qhrE058 PRCf 5 !.!a!!9"b""# $ gd>gd gd  gd def5 6 !!,!-!.!9":"`"a"b"## $ $ $''''''%))))))))8*9*R*S******$+%+&+/+:,;,L,U,, - -K------..ߺׯh;q hdI~hEhE h{Uh{U h1h1 h>h>h hzoh2rhhFYhFJ h{Uhth1 h{UhT> h{UhB_<D $F$j$$$%''q)))9*S**&+/+,;,D,L,, -K--...gd) gd  `gd>gd gd ... . .....6.7.F.DDD{PPPUg[gjjj||'|(|||||5}6}Z}[}\}9=}~ՀRS؅مڅÿչõîãhY hYhYhB_< hB_<hB_<hhFY hFJ@h hwNo h{UhB_< h{Uh{UhFJ h%ch%ch%ch4hNhEh-h h;qh# >..8.../011234467899:;;<U<<=R==>$$gd gd `^``gddI~gd >>?9???-@@@@AA0AAAAB%BABYBkBCGCC D-DD `^``gddI~gd gd DDD6EqEE'F_FFF-GvGG(HH.I]IIII_JJJnKKKgd gd $$gd $$gd $`^``gd KK LtLMM9NNNNN4OO{PPGQhQQ$RR{SSTUUUVgddI~ `^``gddI~gd gd VV"WWEXXYYzZZ[\p\\|]]]^^__[`y``aNaaaagd gddI~gd a'bbb'c3cd7eeef1gUgggVhhjj+jjjlll+mJmgd `^``gddI~gd gddI~Jmrmmn:nnnnno&oxoooooppp qqBqfqqqqqqrgddI~gd gd r+rErYrlr}rrrrrssssst-ttt uuCuVuvuuuuv  ^ `gddI~gddI~gd v*vPvsvvvvvBwfw}wwwwwxEx~xxxxy$yIymyyLzgd gddI~gd  ^ `gddI~Lzzzzz{!{:{R{s{{{{||'|||5}\}}~~~ `gd> gd gd)gd gddI~gd ~ՀO'IRڅ{ӈgd $$$d&d1$NPa$gd gd gd gd  `gd> gd gd {ӈ$ɉԉՉ։݉ (),HIJKʊˊÿÿjhB_<U*hZ ?mHnHujhB_<Uh)h@thB_<B*phh[ hB_<h*fjh*fUhvt hZ ?5h h 5h h ;CJ h h h hwNohY hYhY3Ukd$$IfTl\,$$0$44 layt{T $Ifgd %78\SSSS $Ifgd kd$$IfTl\,$$0$44 layt{T89:;<=^UUUU $Ifgd kd8$$IfTl\,$$0$44 layt{T=>EFHI\SSSS $Ifgd kd$$IfTl\,$$0$44 layt{TIJKLMN^UUUU $Ifgd kdp$$IfTl\,$$0$44 layt{TNOVWXY\SSSS $Ifgd kd $$IfTl\,$$0$44 layt{TYZ[\]^^UUUU $Ifgd kd$$IfTl\,$$0$44 layt{T^_ghij\SSSS $Ifgd kdB$$IfTl\,$$0$44 layt{Tjklmno^UUUU $Ifgd kd$$IfTl\,$$0$44 layt{Topxyz{\SSSS $Ifgd kdz$$IfTl\,$$0$44 layt{T{|}~^UUUU $Ifgd kd$$IfTl\,$$0$44 layt{T\SSSS $Ifgd kd$$IfTl\,$$0$44 layt{T^UUUU $Ifgd kdP$$IfTl\,$$0$44 layt{T\WUUUUUUPgd{Ugd kd$$IfTl\,$$0$44 layt{T gd{U‰ÉĉʼnƉljȉɉʉˉ͉̉ΉωЉщ҉ $$Ifa$gd[ $IfgdZ ?gd{U ()9HWK $$Ifa$gdZ ?Kkd$$IfTH0x$`64 HaT $$Ifa$ $Ifgd[ Kkd$$IfTH0x$`64 HaTHIJKLMf~TGkd $$IfHU0$ $ $4 Hal $$Ifa$$Ifgd{UKkdF $$IfTH0x$`64 HaTϊЊъҊTRMgd{UGkdg $$IfHU0$ $ &$4 Hal $Ifgd;qGkd $$IfHU0$ $ $4 Hal $$Ifa$ $Ifgd[ ˊ͊ΊҊӊԊhvth*fhB_<jhB_<U*hZ ?mHnHu*ҊӊԊgd E....()()))()000?P&P/R 8$BP/ =!"#8$% Dp$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T$$If!vh#v#v#v#v:V l0$5555yt{T]$$If!vh#v#v`:V H655`44 HT]$$If!vh#v#v`:V H655`44 HT]$$If!vh#v#v`:V H655`44 HT_$$Ifl!vh#v #v:V HU$5 544 Hal_$$Ifl!vh#v #v:V HU$5 544 Halk$$Ifl!vh#v #v:V HU$,5 5944 Hal*s2 0@P`p2( 0@P`p 0@P`p 0@P`p 0@P`p 0@P`p 0@P`p8XV~ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@_HmH nH sH tH J`J >Normal1$OJQJ\]_HmH sH tH ZZ > Heading 1$ <@&^ ;CJKH \^JaJ RR > Heading 2$ P 1$@&^  5;CJXX > Heading 3$ h!  1$@&^ 5;mH sH XX )%c Heading 4$<@&5CJOJPJQJ^JaJDA D >Default Paragraph FontVi@V  Table Normal :V 44 la (k (>No List P+@P  Endnote Text,EOS$1$a$5;.. >TOC 9 ^P@P >Footnote Text,Foot Title;X1X > Attachment ID$ !xa$ 5;CJR@2R >Header,Head Project  !;4 B4 >Footer  !>O> )PRT$$ & F1$a$50Ob0 )TITLE5;LOrL PR1,$ & F ``*$1$@&a$NOrN ">ART)$$ & F01$^`0a$;POP # PR2,$ & F *$1$@&a$\>O> >PR3$$ & F1$a$\NON >PR4)$$ & Fp1$^p`a$\NN >PR5)$$ & F 1$^ `a$\HOH ( 0CMT$*$1$a$5;B*\]phRR >Attachment Name$xa$m$ 5;CJb1b >Attachment,Proj Number h!xx^BOB Comment 5;B*CJphHH Y Balloon Text!CJOJQJ^JaJ:/!: >ART Char;OJQJ\]4/14  PR2 Char OJQJ]HrH rE0SUT$$*$1$@&a$CJOJQJ\]HrH rE0DST%$*$1$@&a$CJOJQJ\]&oa& rE0SI B* ph&oq& rE0IP B*ph@/@  0CMT Char5;B*OJQJphV/V %cHeading 4 Char!5CJOJPJQJ\]^JaJPK![Content_Types].xmlN0EH-J@%ǎǢ|ș$زULTB l,3;rØJB+$G]7O٭Vc:E3v@P~Ds |w< Ԃ  +6????Bd.ˊԊFIKMYm  $.>DKVaJmrvLz~8=INY^jo{ HҊԊGHJLNOPQRSTUVWXZ[\]^_`abcdefghijkln$',7:B!tt8@0(  B S  ?TUVQQ_Ղ[ddՂ9*urn:schemas-microsoft-com:office:smarttagsState8*urn:schemas-microsoft-com:office:smarttagsCity=*urn:schemas-microsoft-com:office:smarttags PlaceType Xg}--//w66rA|AVVNYWY|]]c:fDfhh+j5j-l5lqq$ȁɁ҂Ղhalaffffgg%ȁɁ҂Ղ3333((BBL)   CC %K%%%%&&& & &&&6&7&ttсҁԁՁց݁ ),>>IJKL΂т҂Ղ(BBL)T Cf  CC %K%%%%&&& &&&&6&7&ttсҁҁԁՁց݁ ),>>ĂĂ΂тт҂Ղ()>B#Ǥʢ4y$*: Kc &r/&H%.X&c}'&Jk3/-ho2ي+#2217t< <&,=qRa@,l@ALk#_ELZdB.L&VTQf=Tsz*F\ `|b&kkn|smJX [oLmszgB {w Qpx:4^`.^`.88^8`.^`. ^`OJQJo( ^`OJQJo( 88^8`OJQJo( ^`OJQJo(hh^h`. hh^h`OJQJo(^`o( PART - ^`o( SCHEDULE  - ^`o(PRODUCT DATA SHEET  - ``^``o(.``^``o(.^`o(.^`o(.  ^ `o()` ` ^` `o()@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.^`.pLp^p`L.@ @ ^@ `.^`.L^`L.^`.^`.PLP^P`L.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.^`o(.^`o(.^`o(.^`o(.ww^w`o(ww^w`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........^`o(.^`o(.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(^`o(.^`o(..^`o(... ^`o( .... ^`o( ..... ^`o( ...... `^``o(....... `^``o(........^`o(.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.{^`{o(2.03  ^ `o(..  ^ `o(...   ^ `o( ....   ^ `o( .....   ^ `o( ......  ` ^ ``o(.......  ` ^ ``o(........ww^w`o(ww^w`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........^`o(^`o(.^`o(..^`o(... ^`o( .... ^`o( ..... `^``o( ...... `^``o(....... `^``o(........^`o(.^`o(.{^`{o(3.  ^ `o(..  ^ `o(...   ^ `o( ....   ^ `o( .....   ^ `o( ......  ` ^ ``o(.......  ` ^ ``o(........^`o(.^`o(.^`o(.^`o(^`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L. ww^w`o(hH ww^w`o(hH. 0^`0o(hH. 0^`0o(hH... 88^8`o(hH .... 88^8`o(hH ..... 88^8`o(hH ......  `^``o(hH.......  `^``o(hH........^`o(.@^`o(.^`o(.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.*<<Kc `|b <r/.L#_Ec}'kka@o2VT*F\#2=TB {wH% [o217E pxsm,=4yJk3/msl@A ~}|0R<0((&        ي+        &        &         Q        &        &        &h       UTqNY X [ vtzo6kR$?-r-+}/rE0<5:B_<>T>Z ?9R)U{UDV'VhFYa_Qr`^b%c L`g7_:27164E~ -1,&S)Or*f{FJ@ $$$$Ԃ@UnknownG.[x Times New Roman5Symbol3. .Cx Arial7.*{$ Calibri5. .[`)TahomaA$BCambria Math"9@)hEE't*f ZV=nBV=nB%)P4QQ2q)PHP ?ti2!xx.dn WC:\Documents and Settings\JRCollins\Application Data\Microsoft\Templates\CSI_STYLES.dotDemountable PartitionsFitzgerald,Richard W(                           ! " # $ % & ' Oh+'0@      (08Demountable PartitionsALTERATION OF THIS OFFICIAL DOCUMENT IS PROHIBITED WITHOUT EXPRESS WRITTEN PERMISSION BY OFFICE OF CAPITAL PLANNING AND MANAGEMENT AT UT MD ANDERSON CANCER CENTER. CSI_STYLESFitzgerald,Richard W10Microsoft Office Word@ @Xc q@.2@F=IV=n CSI Division SZWXXFYDWACR-487-698%0722a2ab-4c36-4b6b-90e0-a0fb90ede92dthttp://fm/groups/cpm/TRG/odgColl ?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^_`abcdefghijklmnoqrstuvwyz{|}~Root Entry FP_Data p1TablexTkWordDocumentGSummaryInformation(DocumentSummaryInformation8,@CompObjrMsoDataStore P_P_ !"#%&')*+-./0123456789:;B=?@ACDEF  F Microsoft Word 97-2003 Document MSWordDocWord.Document.89qDocument ID GeneratorSynchronous100011000Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Offic1OB2CE4B4C==2 P_P_Item  ePropertiesECCJSJICNBDPQ==2 P_P_Item  x.Properties RJ0GNGQ0EQ==2P_P_Item $Properties(RY35WEKE4PPPEA==2P_P_Item <Properties>ܱ="08"/> This value indicates the number of saves or revisions. The application is responsible for updating this value after each revision. cumentation> This value indicates the number of saves or revisions. The application is responsible for updating this value after each revision. "xsd:string"/> e.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100021001Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100041002Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100061003Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerer>Microsoft.Offi > DocumentLibraryFormDocumentLibraryFormDocumentLibraryForm ՜.+,D՜.+,\x   ; CAPITAL PLANNING AND MANAGEMENT UT MD ANDERSON CANCER CENTERBQ Demountable Partitions Title X<p _dlc_DocId_dlc_DocIdItemGuid_dlc_DocIdUrl Published Date to External SiteReady to PublishStatus