ࡱ> a Tbjbjjj G?b?bJ-JJ8$6i.(***hhhhhhh$Mjm0h!!!h**h2+2+2+!**h2+!h2+2+bZ]:g*&MD"`Vhh0iDa3n"3n:g3n:gP|2+/ d hh%i!!!!3nJB : SECTION 10 22 26.13 folding panel partitions GENERAL RELATED DOCUMENTS Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY Section includes manually operated, acoustical panel partitions. REFERENCE STANDARDS The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date. Reference amendments adopted prior to the effective date of this Contract shall be applicable to this Project. Materials, installation and workmanship shall comply with all applicable requirements and standards. QUALITY ASSURANCE Single Source Responsibility: Obtain folding panel partitions and mounting hardware from one source from a single manufacturer. Testing Laboratory Qualifications: To qualify for acceptance, an independent testing laboratory must demonstrate to Architect's satisfaction, based on evaluation of laboratory submitted criteria conforming to ASTM E 699, that it has the experience and capability to conduct satisfactorily the testing indicated. PREINSTALLATION MEETINGS Preinstallation Conference: Conduct conference at Project site. SUBMITTALS Product Data: For each type of product. Shop Drawings: For operable panel partitions. Include plans, elevations, sections, attachment details[,and numbered panel installation sequence]. Indicate stacking and operating clearances. Indicate location and installation requirements for hardware and track, blocking, and direction of travel. Include diagrams for power, signal, and control wiring. Retain "Samples for Initial Selection" and "Samples for Verification" paragraphs below for two-stage Samples. Samples for Initial Selection: For each type of exposed material, finish, covering, or facing. Include Samples of accessories involving color selection. Samples for Verification: For each type of exposed material, finish, covering, or facing, prepared on Samples of size indicated below: Retain "Textile Facing Material" Subparagraph below for textile wall coverings. Textile Facing Material: Full width by not less than 36-inch- (914-mm-) long section of [fabric] [carpet] from dye lot to be used for the Work, with specified treatments applied. Show complete pattern repeat. Retain "Panel Facing Material" Subparagraph below for facing material other than textiles. Panel Facing Material: Manufacturer's standard-size unit, not less than 3 inches (75 mm) square. Panel Edge Material: Not less than 3 inches (75 mm) long. Chair Rail: Manufacturer's standard-size unit, 6 inches (150 mm) long. Glass: Units 12 inches (300 mm) square. Hardware: One of each exposed door-operating device. Retain "Delegated-Design Submittal" Paragraph below if design services have been delegated to Contractor. Delegated-Design Submittal: For operable panel partitions. Include design calculations for seismic restraints that brace tracks to structure above. Coordination Drawings: Reflected ceiling plans, drawn to scale, on which the following items are shown and coordinated with each other, using input from installers of the items involved: Partition track, track supports and bracing, switches, turning space, and storage layout. Suspended ceiling components. Structural members to which suspension systems will be attached. Size and location of initial access modules for acoustical tile. Items penetrating finished ceiling including the following: Lighting fixtures. HVAC ductwork, outlets, and inlets. Speakers. Sprinklers. Smoke detectors. Access panels. . Plenum [fire] [smoke] [and] [acoustical] barriers. Revise "Setting Drawings" Paragraph below to suit Project. Setting Drawings: For embedded items and cutouts required in other work[,including support-beam, mounting-hole template]. Coordinate "Qualification Data" Paragraph below with qualification requirements in Section014000 "Quality Requirements" and as may be supplemented in "Quality Assurance" Article. Qualification Data: For [Installer] [testing agency]. Retain "Seismic Qualification Certificates" Paragraph below if required by seismic criteria applicable to Project. See ASCE/SEI7 for certification requirements for equipment and components. Seismic Qualification Certificates: For operable panel partitions, tracks, accessories, and components, from manufacturer. Include seismic capacity of partition assemblies to remain in vertical position during a seismic event and the following: Basis for Certification: Indicate whether certification is based on analysis, testing, or experience data, according to ASCE/SEI7. Detailed description of partition anchorage devices on which the certification is based and their installation requirements. Retain "Product Certificates" Paragraph below to require submittal of product certificates from manufacturers. Product Certificates: For each type of operable panel partition. Retain subparagraph below if Owner-furnished material is required to be installed by manufacturer. Include approval letter signed by manufacturer acknowledging Owner-furnished panel facing material complies with requirements. Product Test Reports: For each operable panel partition, for tests performed by a qualified testing agency. Retain "Field quality-control reports" Paragraph below if Contractor is responsible for field quality-control testing and inspecting. Field quality-control reports. Sample Warranty: For manufacturer's special warranty. Operation and Maintenance Data: For operable panel partitions to include in maintenance manuals. In addition to items specified in Section017823 "Operation and Maintenance Data," include the following: Panel finish facings and finishes for exposed trim and accessories. Include precautions for cleaning materials and methods that could be detrimental to finishes and performance. Seals, hardware, track, track switches, carriers, and other operating components. Retain subparagraph below if electric operation is required. Electric operator and controls. QUALITY ASSURANCE Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer. DELIVERY, STORAGE and HANDLING Deliver materials to Project Site in original factory wrappings and containers, clearly labeled with identification of manufacturer, brand name, quality or grade, fire performance characteristics, and lot number. Store panels only on edge, blocked off ground to prevent sagging and warping, in original undamaged packages and containers, inside well ventilated area protected from weather, moisture, soiling, extreme temperatures, and humidity. Comply with instructions and recommendations of manufacturer for special delivery, storage, and handling requirements. SYSTEM PERFORMANCE REQUIREMENTS [UL 723 AND NFPA 255 ARE ESSENTIALLY THE SAME AS ASTM E 84 AND MAY BE SUBSTITUTED FOR IT IF REQUIRED BY AUTHORITIES HAVING JURISDICTION.] Fire Performance Characteristics: Provide folding panel partitions with surface burning characteristics indicated below, as determined by testing assembled materials composed of surface coverings, backings, and other construction identical to those required in this section, per ASTM E 84, by a testing organization acceptable to authorities having jurisdiction. [GENERALLY RETAIN BELOW. RATINGS ARE BROAD ENOUGH TO APPLY TO PRODUCTS INCLUDED AS EXAMPLES IN TEXT. APPLIES TO BOTH NON RATED AND FIRE RATED UNITS.] Flame Spread: 25 or less [BELOW BASED ON CURRENT NFPA CODE UPPER LIMIT FOR FINISH MATERIALS.] Smoke Developed: 450 or less Acoustical Performance: Provide folding panel partitions tested by independent testing laboratory acceptable to authorities having jurisdiction, for the following acoustic properties, according to the test method indicated: Sound Transmission Requirements: Folding panel partition assembly tested in a full scale opening (14 feet by 9 feet) for laboratory sound transmission loss performance in accordance with ASTM E 90, determined by ASTM E 413 and rated for a STC plus or minus 1 as indicated: Sound Transmission Class (STC): Not less than 50 for the specified Model 931/932 Series panels. WARRANTY Special Warranty: Manufacturer agrees to repair or replace components of operable panel partitions that fail in materials or workmanship within specified warranty period. Failures include, but are not limited to, the following: Faulty operation of operable panel partitions. Deterioration of metals, metal finishes, and other materials beyond normal use. Warranty Period: 10 years from Substantial Completion. PRODUCTS GENERAL Materials shall meet or exceed all applicable referenced standards, federal, state and local requirements, and conform to codes and ordinances of authorities having jurisdiction. manufacturers To establish standards of manufacture, operation, performance, and appearance, specifications are based on products of Modernfold Inc. "Acousti-Seal 900 Series", model number as follows: [SELECT FROM THE BELOW LIST AND DELETE THOSE THAT DON'T APPLY.] Model 931, Individual panels Model 932, Paired panels Subject to compliance with requirements, products of the following manufacturers will also be acceptable: Hufcor, Inc. Kwik Wall Co. Modernfold, Inc. Moderco, Inc. PANEL CONSTRUCTION [FOLLOWING IS BASED ON DEFAULT MANUFACTURER "MODERNFOLD ACOUSTISEAL 900 SERIES" AND MAY HAVE TO BE MODIFIED IF PROJECT BASED ON SOMEBODY ELSE.] Provide panel construction, 3 inches thick, consisting of minimum 24 gage steel face sheets welded to minimum 18 gage steel channel frame, factory-fabricated panels, free of joints in faces; panel hanging weight between 8 and 12 pounds per square foot depending upon panel finish. Top reinforcing as required to support hanging from suspension components; internal insulation, internal gasketed edge construction to achieve specified acoustical ratings. [SELECT PANEL FINISH FROM LIST BELOW AND DELETE THOSE THAT DON'T APPLY. MDACC TYPICALLY USES FABRIC WALL COVERING AS the FINISH SURFACE.] Finish: Refer to Interior Finish Legend on Drawings. Finish Surface: Vinyl fabric, factory-applied over steel face sheets. Finish Surface: Vinyl fabric, factory-applied over minimum inch thick gypsum board or high density particleboard (min. 45 lbs./cu. ft.) backing sheet. Finish Surface: Vertical ribbed fusion-bonded carpeting, minimum weight 31 oz./sq. yd.; factory-applied over minimum inch thick high density particleboard (min. 45 lbs./cu. ft.) or inch thick plywood backing sheet. Finish Surface: High pressure decorative laminate, which meets NEMA LD 3 minimum standards, factory-applied to minimum inch thick high density (min. 45 lbs./cu. ft.) fire rated particleboard backing sheet; 0.020" laminated plastic backing sheet on reverse face of particleboard core sheets. Finish Surface: Standard woven Class A fire-rated fabric, factory-applied over minimum inch gypsum board or high density particleboard (min. 45 lbs./cu. ft.) backing sheet, standard panel framing. Finish Surface: Owner-furnished material, factory-wrapped to cover panel face and edges, revealing only fine line joint when panel closed; applied over inch minimum gypsum board or high density particleboard (min. 45 lbs./cu. ft.) backing sheet. Finish Surface: Owner-furnished material, factory-wrapped over inch thick Class A fire rated padding material, to cover panel faces and edges, revealing only fine line joint when panels closed; applied over 1/2" minimum gypsum board or high density particleboard (min. 45 lbs./cu. ft.) backing sheet. Provide operable wall assembly that has been tested by an NSSEA accredited acoustical laboratory in a full-scale (14 feet x 9 feet opening) laboratory sound transmission loss performance test, and has been rated for an STC range of 50-52 (NSSEA Class G) when tested in accordance with ASTM E 90. [VERIFY STC RANGE ABOVE AND MODIFY IF REQUIRED BY PROJECT CONDITIONS.] Vertical Seal: Deep nesting, interlocking astragals incorporating continuous vinyl acoustical seal. Horizontal Top Seal: Continuous contact extruded vinyl. Horizontal Bottom Seal: Retractable seal, extruded vinyl face, exerting positive pressure downward, assuring sealing and resisting panel movement. Minimum clearance between retracted seal and floor finish 1 inch. Extension/retraction of bottom seals automatically actuated by movement of partition. Extended seal exerts nominal 20 lbs. pressure downwards. Provide semi-concealed, butt-type hinges, finished to match other exposed hardware. Provide minimum three hinges per joint for heights up to 8' 0"; one additional hinge for each additional 4' 0" increase in height. Provide the following items in quantities and locations as indicated on Drawings: [DELETE THE FOLLOWING ITEMS THAT DON'T APPLY.] Single Pass Door: Nominal 3' 0" x 7' 0" door, built into panel where indicated; of same basic design, materials, thickness as panel construction; equipped with sound gaskets around entire perimeter of door. Provide minimum 3 semi-concealed ball bearing butt hinges in finish to match other exposed hardware. Double Pass Door: 6'-0" x 7' 0" pair of doors, built into panel where indicated; of same basic design, materials, thickness as panel construction; equipped with sound gaskets around entire perimeter of door. Provide minimum 3 semi-concealed ball bearing butt hinges each leaf, in finish to match other exposed hardware. Provide tool-operated retractable floor seal on panels containing pass doors; sweep type panel floor seals are not acceptable. Pocket Door: Full height pocket doors at end of partition runs where indicated on Drawings to conceal "stacked" partition. Construct of same basic design, materials, thickness and acoustical qualities as panels. Provide standard-bearing butt hinges in finish to match other exposed hardware. Provide acoustical seals at soffit, floor and jambs. Provide key-operated rim lock to secure pocket door in closed position. SUSPENSION SYSTEMS Carriers: Four wheel at lead post and two wheel at intermediate spacing as required for size and weight of partition for ease of operation. Suspension Tracks: Heavy duty steel or aluminum, with overhead supports of adjustable steel hanger rods; heavy duty, ball bearing, trolley system supports specifically designed for use with size and type folding panel partition assembly indicated. Track deflection independent of structural support system no more than 1/360th of opening width. POSTS AND SEALS Lead posts and jamb posts formed to provide rigidity for partition and light seal at adjacent construction. [SELECT FROM BELOW OR MODIFY.] Post Type: Floating or attached multiple meeting post with 2, 3, or 4 way meeting arrangements. Post Type: Intermediate post, one side. Post Type: Intermediate post, both sides. Sound Seals: Perimeter sweep strips for each side, top, and bottom; providing continuous contact with head and sill surfaces for positive light and sound seal. Include manufacturer's standard male and female sound and light seal at lead post and jamb. Vertical Seals: Deep nesting, interlocking astragals with continuous vinyl acoustical seal. Horizontal Top Seals: Continuous contact extruded vinyl or mechanical retractable vinyl faced seal exerting positive pressure on track when extended. [REVISE CLEARANCE DIMENSION BELOW AS REQUIRED TO ACCOMMODATE ANTICIPATED STRUCTURE AND FLOOR DEFLECTIONS AND IRREGULARITIES.] Horizontal Bottom Seals: Retractable seal exerting positive pressure downward assuring horizontal and vertical sealing and resisting panel movement. Minimum clearance between retracted seal and floor finish shall be 1 inch. Extension/retraction of bottom seals automatically actuated by movement of partition. Bottom seal shall be continuous contact extruded vinyl. [IF BI PARTING OPENING SPECIFIED, CARRIER STOP AND SECOND FINAL CLOSURE ARE REQUIRED.] Final Closure: Positive mechanical closure expanding from panel edge to create positive acoustical seal. [REVISE BELOW OR MODIFY FOR OTHER CLOSURE OPTIONS.] Jamb hinged closure. Hinged communicating panel. EXECUTION PREPARATION Examine flooring for compliance with requirements for installation tolerances and other conditions affecting performance of folding partitions. Do not proceed with installation until unsatisfactory conditions have been corrected. INSTALLATION Installation shall meet or exceed all applicable federal, state and local requirements, referenced standards and conform to codes and ordinances of authorities having jurisdiction. All installation shall be in accordance with manufacturers published recommendations. Install folding panel partitions and accessories in compliance with ASTM E 557 after other finishing operations including painting, have been completed. Install folding panel partitions in conformance with drawings and approved shop drawings and in strict compliance with manufacturer's written installation instructions. Match folding panel partitions for color and pattern by installing partitions from cartons in same sequence as manufactured and packaged, if so numbered. Broken, cracked, chipped, or deformed partitions are not acceptable. Repair or replace folding panel partitions within areas where test results indicate partitions do not comply with requirements and retest partitions. [NOTE: NOISE ISOLATION COEFFICIENT (NIC) IS AN IN PLACE FIELD TEST VALUE AND DOES NOT CORRELATE WITH LABORATORY STC VALUES. THIS TEST IS APPROPRIATE FOR PARTITIONS WITH STC RATING HIGHER THAN 48. FIELD TEST VALUE OF NIC IS GENERALLY 8 TO 10 POINTS LOWER THAN LAB NIC VALUE.] [THE NIC VALUE SHOULD TAKE INTO ACCOUNT ALL PARTITIONS OF JOB SINCE WIDTH, HEIGHT, PERIMETER OF OPENING, AND FLOOR SURFACE AFFECT NIC. MFR AND/OR ACOUSTICAL CONSULTANT SHOULD BE CONSULTED TO ARRIVE AT A MUTUALLY AGREEABLE NIC VALUE FOR PROJECT.] FIELD TESTS Owner will engage an independent testing service to provide in-place tests of each operable partition for Noise Isolation Class (NIC). Tests for measurement of noise isolation between rooms will be performed in general conformance with ASTM E 336; NIC rating will be calculated in accordance with ASTM E 413. If any operable partition does not initially meet NIC requirements stated above, installer will be responsible for modifying and adjusting partition assembly as required, after which partition will be retested until compliance is achieved. Owner will pay cost of initial in-place field test for each operable partition. Cost of additional testing will be borne by the Contractor. ADJUSTING Lubricate bearings and sliding parts; adjust to ensure smooth, easy operation. CLEANING Clean all folding partition surfaces and clean adjacent surfaces soiled by Work of this section. Avoid use of abrasive cleaners or solutions containing corrosive solvents. Use cleaning materials recommended by manufacturer. END OF SECTION 10 22 26.13 FOR MDACC USE ONLY. DELETE THIS PAGE BEFORE ISSUING DOCUMENTS. document revision history IssueDateRevision DescriptionAuthor20190301Original IssuanceRev. 1.Rev. 2Rev. 3 Rev. 4 Rev. 5    MD ANDERSON Project No. XXXXXXMD Anderson PROJECT NAMEA/E Name Issue Description A/E Project No.Month 00, 0000 鶹ӳ folding panel partitions MD Anderson Cancer Center10 22 26.13 MS 20190301 PAGE 11 of  NUMPAGES 11 -.GH  1 2  ( Y \ * 8 O P C m ?MRZdv|Iغغسغسh[h@9y5h[h@9y0J&B*phh[h@9y0J'B*ph h[h@9y hh@9yh@9yh@9y5h/dh hbh@9yh@9yh-,h);D h I@h I h[h I h[hhuKz9.6H 2   P i p ? FgdgdFgdFgdFgdFgdFI+S-A;w&agdFgdFgdgdF$8AJ  &a{+y#`  - B I J N a"b"" #x$%)%*%B%F%o%'))))J*W*X*+S++ӽӽӹhF7 hz2hannh-,hh I hbh@9yh@9yh@9y5 h@9yh@9yh@9y hh@9yh[h@9y0J'B*ph h[h@9yh[h@9y0J&B*phAz{+ yT#` - !!b""gdFgdFgdFgdgdF" #x$%*%o%%n&'''(((N))))J*X*+S+p+++,,gdFgdFgdFgdFgdFgd++,.,A,,,,,,.. /"/X///0000112233<4B4555555T66 8899 A,ACQDEFFFFFGHHHKM1Q5QQQQQ"RüöòDz宧 hhWhWh/d h I@ h/dh/dh I hYhz2hGhkeh[hJY hz2hz2h-,hWb hz2hannh#;hh `?, ,.,A,,."/X//901;233,5T6679788x999/;q<<gdFgdFgdgdFgdF<M>>>5?@@ A,AAAABO> FPRT$$ & F1$a$50Ob0 FTITLE5;JOrJ FPR1)$$ & F81$^8`a$TOrT "FART0$$ & F `01$^`0a$;FOF #FPR2!$$ & F1$`a$\>O> FPR3$$ & F1$a$\NN );DPR4)$$ & Fp1$^p`a$\NN );DPR5)$$ & F 1$^ `a$\HOH (0CMT$*$1$a$5;B*\]phRR );DAttachment Name$xa$m$ 5;CJb1b );DAttachment,Proj Number h!xx^BB FComment 5;B*CJphHH l Balloon Text!CJOJQJ^JaJ:/!: FART Char;OJQJ\]4/14 FPR2 Char OJQJ]HrH @9ySUT$$*$1$@&a$CJOJQJ\]HrH @9yDST%$*$1$@&a$CJOJQJ\]&oa& @9ySI B* ph&oq& @9yIP B*ph@/@ 0CMT Char5;B*OJQJphPK![Content_Types].xmlN0EH-J@%ǎǢ|ș$زULTB l,3;rØJB+$G]7O٭Vc:E3v@P~Ds |w< "',,,/+"+.15",<G=RiRRRRRRRRRRRRRR SSST,-/02346789:;<=>?@ABCDEFG $'/!tt8@0(  B S  ?  5 5 5 5 5 5 5 5 5 5 5 5\.\.`.112/3/363KKKL   _.e.e.12253:3:3KKKL  9 *urn:schemas-microsoft-com:office:smarttagsplace= *urn:schemas-microsoft-com:office:smarttags PlaceName= *urn:schemas-microsoft-com:office:smarttags PlaceType  """"##$$ $'$T&\&JJJJJJJJJKKLL;C(!(**33JJJJJJJJJKKLL333333366(P   BFoo!!!""S#S#####$-$.$.$$$$$& '!'!'"'X';*;*.. 0 0000011q4q44488 9,9;Q<=>>>>>CEHHGIGIIJJJJJKKKKKKKKKKKKKKKKK L L L L LLL.66(P BBFGtu!!!""X#Y##########$-$.$.$3$4$$$$$&&&& '!'!'"'X'^'_';*;*.. 0 0 0000012x4y444888 9 999999 9"9#9+9,909;;;;;;;;;;;;;<<<<<<<<%<&<)<*</<0<;<<<?<@<P<Q<[<=====================>>> > > >>>>|>>>>>>>>>>>>>>>>>>>>>>CDDEHHGIGILIIJJJJJJJJJJJJKK K K KK#K#K*K+K,K4KBKEK`KcKuKuKKKKKKKKKKKLL(|})S~>B#Ǥʢ4y$*: Kc &r/&H%.X&c}'&Jk3/-ho2ي+#2217t< <&,=qRa@,l@ALk#_ELZdB.L&VTQf=Tsz*F\ `|b&kkn|smJX [oLmszgB {w Qpx:4^`.^`.88^8`.^`. ^`OJQJo( ^`OJQJo( 88^8`OJQJo( ^`OJQJo(hh^h`. hh^h`OJQJo(^`o( PART - ^`o( SCHEDULE  - ^`o(PRODUCT DATA SHEET  - ``^``o(.``^``o(.^`o(.^`o(.  ^ `o()` ` ^` `o()@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.^`.pLp^p`L.@ @ ^@ `.^`.L^`L.^`.^`.PLP^P`L.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.^`o(.^`o(.^`o(.^`o(.ww^w`o(ww^w`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........^`o(.^`o(.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(^`o(.^`o(..^`o(... ^`o( .... ^`o( ..... ^`o( ...... `^``o(....... `^``o(........^`o(.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.{^`{o(2.03  ^ `o(..  ^ `o(...   ^ `o( ....   ^ `o( .....   ^ `o( ......  ` ^ ``o(.......  ` ^ ``o(........ww^w`o(ww^w`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........^`o(^`o(.^`o(..^`o(... ^`o( .... ^`o( ..... `^``o( ...... `^``o(....... `^``o(........^`o(.^`o(.{^`{o(3.  ^ `o(..  ^ `o(...   ^ `o( ....   ^ `o( .....   ^ `o( ......  ` ^ ``o(.......  ` ^ ``o(........^`o(.^`o(.^`o(.^`o(^`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L. ww^w`o(hH ww^w`o(hH. 0^`0o(hH. 0^`0o(hH... 88^8`o(hH .... 88^8`o(hH ..... 88^8`o(hH ......  `^``o(hH.......  `^``o(hH........^`o(.@^`o(.^`o(.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.*<<Kc `|b <r/.L#_Ec}'kka@o2VT*F\#2=TB {wH% [o217E pxsm,=4yJk3/msl@A ~}|R<0((&        ي+        &        &         Q        &        &        &h       NM1N? G8)CaET F7#;);DnF ILKQQtXnYZ ZK `/ddh]'klann@9yN=zuKz|1C} z2,L$JY `Ff{zCO"Wb4/DbY zYYZt[n59&A| N;0GGYTVWsf-, n?mtkeJJ@JJJJLx@UnknownG.[x Times New Roman5Symbol3. .Cx Arial5. .[`)TahomaA$BCambria Math"9@)hދ&ti- ? &- ? &!)P4JJ2Q)PHP ?dh2!xx } WC:\Documents and Settings\JRCollins\Application Data\Microsoft\Templates\CSI_STYLES.dotFolding Panel PartitionsHernandez,Marietta L(                           ! " # $ % & ' Oh+'0D     $,4<Folding Panel PartitionsALTERATION OF THIS OFFICIAL DOCUMENT IS PROHIBITED WITHOUT EXPRESS WRITTEN PERMISSION BY OFFICE OF CAPITAL PLANNING AND MANAGEMENT AT UT MD ANDERSON CANCER CENTER. CSI_STYLESHernandez,Marietta L31Microsoft Office Word@]n2@P@Tָ@LM - ? CSI Division SZWXXFYDWACR-487-699%500fb757-144a-485a-87a3-e93324158fc2thttp://fm/groups/cpm/TRG/odgCollmentManagement.Internal.DocIdHandler/metadata/longProperties"/> ?@ABCDEFGHJKLMNOPRSTUVWXYZ[\]^_`abcdefghijklmnopqrstuvwxyz{|}~Root Entry F= _Data I1TableQnWordDocumentGSummaryInformation(DocumentSummaryInformation8,@CompObjrMsoDataStore  _ _  !"#$%&'()*+<-./0123456789:;B=?@ACDEF  F Microsoft Word 97-2003 Document MSWordDocWord.Document.89qDocumentLibraryFormDocumentLibraryFormDocumentLibraryForm ܱ="08"/> This value indicates the number of saves or revisions. The application is responsible for updating this value after each revision. cumentation> This value indicates the number of saves or revisions. The application is responsible for updating this value after each revision. "xsd:string"/> ns:ds="http://schemas.openxmlformats.org/officeDocument/2006/customXml"/>1000Microsof Filter>Document ID Generator Token=71e9bce111e9429cMicrosoft.OfficDocument ID GeneratorSynchronous100011000Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100021001Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100041002Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100061003Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.Docu ՜.+,D՜.+,\x   = CAPITAL PLANNING AND MANAGEMENT UT MD ANDERSON CANCER CENTER@&J Folding Panel Partitions Title X<p _dlc_DocId_dlc_DocIdItemGuid_dlc_DocIdUrl Published Date to External SiteReady to PublishStatus