ࡱ> _ Gebjbjzyzy G6b6b\522222FFF8~<Fef(& eeeeeee$giB(e2"""(e22=e4f'f'f'"22ef'"ef'f'bY`:cI#\Vdqe<eD] kL$ k:c k2:c |f' !dq!S(e(e%e"""" kB : SECTION 10 51 13 metal lockers GENERAL RELATED DOCUMENTS Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY Section includes: Metal lockers. Locker benches. REFERENCE STANDARDS The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date. Reference amendments adopted prior to the effective date of this Contract shall be applicable to this Project. Materials, installation and workmanship shall comply with all applicable requirements and standards. QUALITY ASSURANCE Uniformity: Provide metal lockers that are standard products of single manufacturer, with interchangeable like parts. Include necessary mounting accessories, fittings, and fastenings. PREINSTALLATION MEETINGS Preinstallation Conference: Conduct conference at Project site. SUBMITTALS Product Data: For each type of product. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for each type of metal locker[and bench]. Shop Drawings: For metal lockers. Include plans, elevations, sections, and attachment details. Show locker trim and accessories. Include locker identification system and numbering sequence. Retain "Samples" Paragraph below for single-stage Samples, with a subordinate list if applicable. Retain "Samples for Initial Selection" and "Samples for Verification" paragraphs for two-stage Samples. Samples: For each color specified, in manufacturer's standard size. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available. Samples for Verification: For the following products, in manufacturer's standard size: Lockers and equipment. Locker benches. Product Schedule: For lockers.[Use same designations indicated on Drawings.] Coordinate "Qualification Data" Paragraph below with qualification requirements in Section014000 "Quality Requirements." Qualification Data: For Installer. Sample Warranty: For special warranty. Maintenance Data: For adjusting, repairing, and replacing locker doors and latching mechanisms to include in maintenance manuals. DELIVERY, STORAGE, AND HANDLING Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for their installation. Deliver [master and control keys] [combination control charts] to Owner by registered mail or overnight package service[.][,addressed as follows:] . FIELD CONDITIONS Field Measurements: Verify actual dimensions of recessed openings by field measurements before fabrication. COORDINATION Delete first paragraph below if only metal legs or continuous metal bases are required. Coordinate sizes and locations of [concrete] [concrete masonry] [wood] bases for metal lockers. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of work specified in other Sections to ensure that metal lockers can be supported and installed as indicated. WARRANTY Special Warranty: Manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period. Failures include, but are not limited to, the following: Structural failures. Faulty operation of latches and other door hardware. Damage from deliberate destruction and vandalism is excluded. Verify available warranties and warranty periods for units and components. Warranty Period for Knocked-Down Metal Lockers: Two years from date of Substantial Completion. Warranty Period for Welded Metal Lockers: [Lifetime] [10 years] from date of Substantial Completion. PRODUCTS GENERAL Materials shall meet or exceed all applicable referenced standards, federal, state and local requirements, and conform to codes and ordinances of authorities having jurisdiction. Lockers shall not have Manufacturer branding or logo. Source Limitations: Obtain metal lockers[,locker benches,] and accessories from single source from single locker manufacturer. Obtain locks from single lock manufacturer. PERFORMANCE REQUIREMENTS Generally, retain applicable "Accessibility Standard" Paragraph below. Accessibility Standard: For lockers indicated to be accessible, comply with applicable provisions in [the USDOJ's "2010 ADA Standards for Accessible Design"] [the ABA standards of the Federal agency having jurisdiction] [and] [ICCA117.1][Texas Accessibility Standards (TAS)]. manufacturers Republic Storage Systems, LLC "Quiet" steel lockers are specified as the type, function, and quality required. [standard steel lockers may be specified in lieu of quiet type where optimal ventilation is required. choose type to suit project requirements] Products of the following manufacturers are acceptable, contingent upon providing products which are equivalent to or exceed the type, function, and quality specified, and are in compliance with the requirements of this Section: De Bourgh Manufacturing Co. Interior/Medart List Industries Inc. Lyon Metal Products Penco Products Inc. MATERIALS AND FABRICATION Provide steel lockers with vented door panel as specified herein. Provide the following arrangements and sizes as indicated on the Drawings: [SELECT REQUIRED SIZES AND CONFIGURATIONS FROM BELOW AND DELETE THE REST. MODIFY AS REQUIRED.] Locker Type 1: Double tier units; each locker 12 inches wide x 12 inches deep x 36 inches high. Locker Type 2: Double tier units; each locker 12 inches wide x 18 inches deep x 36 inches high. Locker Type 3: Single tier units; each locker 12 inches wide x 12 inches deep x 72 inches high. MATERIALS Sheet Steel: Mild cold rolled and leveled furniture steel, free from buckle, scale, and surface imperfections. Expanded Metal: 3/4 inch mesh flattened carbon steel. Fasteners: Cadmium, zinc, or nickel plated steel; exposed bolt heads, slotless type; self locking nuts or lock washers for nuts on moving parts. Equipment: Hooks and hang rods of cadmium plated or zinc plated steel. FABRICATION, GENERAL Construction: Fabricate lockers square, rigid, and without warp, with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch. Weld frame members together to form rigid, one piece structure. Weld, bolt, or rivet other joints and connections. Grind exposed welds flush. Do not expose bolts or rivet heads on fronts of locker doors or frames. FINISHES, GENERAL Finish all steel surfaces and accessories, except prefinished stainless-steel and chrome-plated surfaces. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. Surface Preparation: Clean surfaces of dirt, oil, grease, mill scale, rust, and other contaminants that could impair paint bond. Use manufacturer's standard methods. Baked-Enamel Finish: Immediately after cleaning and pretreating, apply manufacturer's standard baked-enamel finish consisting of a primer and a thermosetting topcoat. Comply with paint manufacturer's written instructions for applying and baking to achieve a minimum dry film thickness of 1.4 mils (0.036 mm) on doors, frames, and legs, and 1.1 mils (0.028 mm) elsewhere. [CUSTOM COLORS ALSO AVAILABLE FROM MOST MFRS.] Color: Provide locker units in color(s) selected by Architect from manufacturer's complete line (15 choices minimum) of available colors. Concealed parts may be manufacturer's standard neutral color. WARDROBE LOCKERS Body: Fabricate back and sides of minimum 24 gage steel, with double flanged connections extending full height. Form top and bottom of not less than 24 gage steel, with flanged edges. Provide 24 gage, steel sheet hat shelf in single tier units. [DELETE BELOW IF ALL LOCKERS RECESSED.] Form exposed ends of non recessed lockers of minimum 16 gage steel. [NARROW (9"12") DOORS MAY BE FABRICATED OF 18 GA. MATERIAL] Door: One piece, minimum 16 gage sheet steel, flanged at all edges, constructed to prevent springing when opening or closing. Fabricate to swing 180 degrees. Reinforcing: Provide extra bracing or reinforcing on inside of doors over 15 inches wide. Ventilation: Provide slots at full perimeter of opening. [DELETE either above or below. quiet lockers have perimeter ventilation, and standard lockers use louvers.] Ventilation: Provide stamped, louvered vents in door face, as follows: Single tier lockers: Not fewer than 6 louver openings top and bottom. Double tier lockers: Not fewer than 3 louver openings top and bottom. Hinges: Steel, full loop, 5 knuckle, tight pin. Weld to inside of frame and secure to door with not fewer than 2 factory installed fasteners that are completely concealed and tamperproof when door is closed. Provide at least 3 hinges for each door over 42 inches high; at least 2 hinges for each door 42 inches high or less. Handle and Latch: Positive automatic, non-protruding, prelocking, pry resistant latch and pull; 14 gage plastic covered, heavy duty, vandalproof lift up handle, with strike and eye for padlock. A 20 gage stainless steel recessed pocket containing the latch and handle shall be provided. Acoustical Treatment: Provide construction treatment designed for significant reduction of noise of locker operation, including protected sound absorbing material; nylon or plastic coatings on operating components to prevent metal to metal contact, and latching mechanism designed to operate without rattling. LOCKER ACCESSORIES Equipment: Furnish each locker with the following items, unless otherwise shown: Single Tier Units: Hat shelf, one double prong rear hook and not fewer than 2 single prong side hooks. Double Tier Units: One double prong rear hook and not fewer than 2 single prong side hooks. Lockers 18 inches Deep: Provide hang rod in lieu of hook. Multi-tier Lockers with space between Vertical Components: Provide chrome plated hang rod between verticals. Number Plates: Manufacturer's standard etched, embossed, or stamped, nonferrous metal number plates with numerals not less than 1/2 inches high. Number lockers in sequence as directed by Architect. Attach plates to each locker door, in latch recess, with at least 2 fasteners of same finish as number plate. [delete below if lockers are fully recessed] Continuous Sloping Tops: Not less than 20 gage sheet steel, approximately 25 degrees pitch, in lengths as long as practicable but not less than 4 lockers. Provide closures at ends. Finish to match lockers. [DELETE BELOW IF ONLY SINGLE TIER LOCKERS, OR OTHERWISE NOT REQUIRED.] Separators: Provide horizontal dividers of not less than 16 gage sheet steel between doors of multiple tier lockers to ensure rigidity. [DELETE BELOW IF NONE RECESSED.] Trim: Provide trim at jambs and head of recessed lockers, consisting of not less than 18 gage cold rolled steel. Factory finish trim to match lockers. Secure trim to lockers with concealed fastening clips. [DELETE BELOW UNLESS KNOWN TO BE NEEDED.] Filler Panels: Provide filler panels where indicated, of not less than 18 gage steel sheet, factory fabricated and finished to match locker units. [delete below if not required] Base: Where indicated, provide 4 high 16 gage metal base, factory fabricated and finished to match locker units. Recess base from front face of lockers. Accessible Lockers: For lockers indicated to be accessible, provide shelf in locker located no lower than 9 above finished floor surface. Provide accessibility symbol graphics at exterior of locker door. Completed installation shall comply with requirements of the Americans with Disabilities Act (ADA). LOCKS Retain required locking device(s) and options in this article as required for locker type(s) in other Part2 articles. If retaining more than one kind of operation for a lock type, indicate location of each on Drawings or by inserts. Combination Padlock: [Key-controlled, three-number dialing combination locks; capable of five combination changes] [Provided by Owner]. Built-in Combination Lock: Key-controlled, three-number dialing combination locks; capable of at least five combination changes made automatically with a control key. Bolt Operation: [Manually locking deadbolt] [or] [automatically locking spring bolt]. Lock in "Cylinder Lock" Paragraph below are deadbolt locks, surface mounted on inside of door, with only the cylinder exposed on outside; revise to suit Project. Cylinder Lock: Built-in, flush, cam lock with five-pin tumbler keyway, keyed separately and master keyed. Furnish two change keys for each lock and two master keys. Key Type: [Flat] [Grooved][,with minimum 2- by 2.68-inch (51- by 68.3-mm) key head for accessible lockers]. Bolt Operation: [Manually locking deadbolt] [or] [automatically locking spring bolt]. "Built-in, Card-Operated Lock" and "Digital Keypad Lock" paragraphs below are often used for accessible lockers, are available from locker manufacturers on a limited basis, and are typically not standard. Retain if required and indicate types of metal lockers that are to be so equipped. Card-operated lock in "Built-in, Card-Operated Lock" Paragraph below requires a projecting handle. Built-in, Card-Operated Lock: Self-contained units mounted on interior of door with replaceable lock cylinders keyed separately and master keyed. Mount instruction decals on both door faces. Furnish one change card key for each lock and one master card key. Bolt Operation: [Manually locking deadbolt] [or] [automatically locking spring bolt]. Digital Keypad Lock: Battery-powered electronic keypad with reprogrammable manager and owner codes that override access. Three consecutive incorrect code entries shall disable lock for three minutes. Retain one of two subparagraphs below. Designed for permanently assigned access via entry of user's four-digit code. Designed for shared or temporary access by multiple users, with user-defined code to lock and unlock. Provide LED indicator to show when lock is in use. LOCKER BENCHES Manufacturers: Obtainbenches and accessories from the same manufacturer of lockers or manufacturers associated supplier. Obtain benches from single manufacturer. If accessible benches are not positioned against a wall, back support is required. Verify, with manufacturers, the availability of back support on accessible benches before adding requirement to the Section Text. Provide bench units with overall assembly height of 17-1/2 inches (445 mm). Bench Tops: Manufacturer's standard one-piece units, with rounded corners and edges. Retain option in "Size" Subparagraph below for accessible benches. Size: Minimum 9-1/2 inches wide by 1-1/4 inches thick (241 mm wide by 32 mm thick)[except provide 20- to 24-inch- (508- to 610-mm-) wide tops where accessible benches are indicated]. Retain one of three subparagraphs below. Laminated clear hardwood with one coat of clear sealer on all surfaces and one coat of clear lacquer on top and sides. Plastic laminate over particleboard core, with two steel tubes running full length of top and positioned to receive pedestal fasteners. Color: [Match metal lockers] [As indicated by manufacturer's designations] [Match Architect's sample] [As selected by Architect from manufacturer's full range]. Extruded aluminum with clear anodic finish. Retain "Fixed-Bench Pedestals" or "Movable-Bench Pedestals" Paragraph below. Fixed-Bench Pedestals: Manufacturer's standard supports, with predrilled fastener holes for attaching bench top and anchoring to floor, complete with fasteners and anchors, and as follows: Retain one of two "Tubular Steel" subparagraphs below or revise to suit Project. Tubular Steel: 1-1/2-inch- (38-mm-) diameter steel tubing threaded on both ends, with standard pipe flange at top and bell-shaped cast-iron base; with baked-enamel or powder-coat finish; anchored with exposed fasteners. Color: [Match metal lockers] [As indicated by manufacturer's designations] [Match Architect's sample] [As selected by Architect from manufacturer's full range]. Tubular Steel: 1-1/4-inch- (32-mm-) diameter steel tubing, with 0.1265-inch- (3.2-mm-) thick steel flanges welded at top and base; with [baked-enamel] [zinc-plated] finish; anchored with exposed fasteners. Retain "Color" Subparagraph below if retaining "baked-enamel" option in second "Tubular Steel" Subparagraph above. Color: [Match metal lockers] [As indicated by manufacturer's designations] [Match Architect's sample] [As selected by Architect from manufacturer's full range]. Movable-Bench Pedestals: Manufacturer's standard supports, with predrilled fastener holes for attaching bench top, complete with fasteners, and as follows: Retain "Aluminum" or "Stainless Steel" Subparagraph below or revise to suit manufacturer's proprietary product. Aluminum: 1/8-inch-thick by 3-inch-wide (3-mm-thick by 76-mm-wide) channel or 1/4-inch-thick by 3-inch-wide (6-mm-thick by 76-mm-wide) bar stock, shaped into [trapezoidal] [inverted-T] form; with nonskid pads at bottom. Finish: [Clear] [Black] [Gold] anodic finish. Stainless Steel: 1/8-inch-thick by 3-inch-wide (3-mm-thick by 76-mm-wide) channel or 1/4-inch-thick by 3-inch-wide (6-mm-thick by 76-mm-wide) bar stock, shaped into trapezoidal form; with nonskid pads at bottom. Finish: [Manufacturer's standard] [No.4B]. Materials: Stainless Steel: ASTMA666, Type304. Plastic Laminate: NEMALD3, GradeHGP. Extruded Aluminum: ASTMB221 (ASTMB221M), alloy and temper recommended by aluminum producer and manufacturer for type of use and finish indicated. Steel Tube: ASTMA500/A500M, cold rolled. FABRICATION Fabricate metal lockers square, rigid, without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs. Form body panels, doors, shelves, and accessories from one-piece steel sheet unless otherwise indicated. Provide fasteners, filler plates, supports, clips, and closures as required for complete installation. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments. Equipment: Provide each locker with an identification plate and the following equipment: Revise "Single-Tier Units," "Double-Tier Units," or "Triple-Tier Units" Subparagraph below to suit Project. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks. Double-Tier Units: One double-prong ceiling hook and two single-prong wall hooks. Retain "Coat Rods" Subparagraph below if required. Coat Rods: [As indicated on Drawings] [For each compartment of each locker] [In lieu of ceiling hook for metal lockers 24 inches (610 mm) high or more] [In lieu of ceiling hook for metal lockers 18 inches (457 mm) deep or more]. Retain "Knocked-Down Construction" or "Welded Construction" Paragraph below. Coordinate with products selected. Knocked-Down Construction: Fabricate metal lockers by [assembling at Project site] [preassembling at plant prior to shipping], using manufacturer's nuts, bolts, screws, or rivets. Welded Construction: Factory preassemble metal lockers by welding all joints, seams, and connections; with no bolts, nuts, screws, or rivets used in assembly of main locker groups. Factory weld main locker groups into one-piece structures. Grind exposed welds smooth and flush. Accessible Lockers: Fabricate as follows: Locate bottom shelf no lower than 15 inches (381 mm) above the floor. Where hooks, coat rods, or additional shelves are provided, locate no higher than 48 inches (1219 mm) above the floor. Continuous Zee Base: Fabricated in lengths as long as practical to enclose base and base ends; finished to match lockers. Continuous Sloping Tops: Fabricated in lengths as long as practical, without visible fasteners at splice locations; finished to match lockers. Retain subparagraph below where two runs of metal lockers meet at right angles. Sloping-top corner fillers, mitered. Recess Trim: Fabricated with minimum 2-1/2-inch (64-mm) face width and in lengths as long as practical; finished to match lockers. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel. Boxed End Panels: Fabricated with 1-inch- (25-mm-) wide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers. Provide one-piece panels for double-row (back-to-back) locker ends. Finished End Panels: Fabricated to conceal unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers. Provide one-piece panels for double-row (back-to-back) locker ends. Center Dividers: Full-depth, vertical partitions between bottom and shelf; finished to match lockers. EXECUTION EXAMINATION Examine walls and floors or support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work. Proceed with installation only after unsatisfactory conditions have been corrected. INSTALLATION Installation shall meet or exceed all applicable federal, state and local requirements, referenced standards and conform to codes and ordinances of authorities having jurisdiction. Install metal lockers at locations shown in accordance with manufacturer's instructions for plumb, level, rigid, and flush installation. Assemble knocked-down lockers with standard fasteners, with no exposed fasteners on door faces and face frames. Connect groups of all-welded lockers together with standard fasteners, with no exposed fasteners on face frames. Anchor lockers to floors and walls at intervals recommended by manufacturer, but not more than 36 inches (910 mm) on center. Install anchors through back-up reinforcing plates where necessary to avoid metal distortion, using concealed fasteners. Install trim, metal base, sloping top units, and metal filler panels and end panels, using concealed fasteners. Provide flush, hairline joints against adjacent surfaces. ADJUST AND CLEAN Adjust doors and latches to operate easily without binding. Verify that integral locking devices are operating properly. Touch up marred finishes, but replace units that cannot be restored to factory finished appearance. Use only materials and procedures recommended or furnished by locker manufacturer . PROTECTION Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit use during construction. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by locker manufacturer. END OF SECTION 10 51 13 FOR MDACC USE ONLY. DELETE THIS PAGE BEFORE ISSUING DOCUMENTS. document revision history IssueDateRevision DescriptionAuthor20190301Original IssuanceRev. 1.Rev. 2Rev. 3 Rev. 4 Rev. 5    MD ANDERSON Project No. XXXXXXMD ANDERSON PROJECT NAMEA/E Name Issue Description A/E Project No.Month 00, 0000 鶹ӳ metal lockersMD Anderson Cancer Center10 51 13 MS 20190301 PAGE 13 of  NUMPAGES 13 89At    ; ? d e x 0 1 P Z   .Y\9PSm   ؿطسإجططططإجطططج؞ h(#h= h=h= hzh=h/(h=h=5 h/(h= hI!hI! h/(h,5h,5h=h<hhKz hR@hR h/(hR h/(hI!>'9   f x 1 J ]   )gdzgdAgdzgd[gd[gdAgd[)\"0 v;M$ *$@&gd=gd[gdzgdzgd[6`C\51~gdAgd[gd[gdAgdzgdz ailt^_`BC\ ?B}5V_]^NU^_fpwڿڻڬڨڬڬڨڬhh ahN hNhNhwhKz hI!hI!h$ h%h.nGh2hI! hzh=hW h=h=hRh=h=5h=B&07=>%%#&$&%&''''''''(((((((())))<*=*>*?*~,,,,,,-D-d-u-v-x-A/F/m/q/////01h1w1111222222~33h,Thah:h9MhOTh` h5ihM hyhyhoPhN hNhNhwhRhhI!h aH>H~U!g!!V"#$%%&&&''(a((=)))?**gdAgd[gd[gdz**++X,-x-../y//0}01122~33o44,5K5577gdAgd[gd[gdzgd@'3333o4p4444+5,55677788y8|889/:::: ;;;=:?a?l@t@@ABBBpBBBBCC%C7CkCC`EEjFFιβΤΛΌβ h=0J) h=0J*h|_h=0J)h|_h=0J* hth= h=0J)5 h=0J*5 hNh= hfh= hzh=h=hQh|/h/hRh> h>h>hI!h hw h h 4788799/::A;;<=>r>:?a??H@W@@@ABpBBkCC DDgd[gdzgd[gdzD4E`EEjFFG8HIyIJJ&KL0LM0M;MbMM NMNYNO|OO~Pgd[gd[gdzgdzgd=FFFFGHRH[HxHHHHHHHIyIJ&K0KMKhKtKKKKKKK LLLLLLAL^LyLLLLMMMPCQQ"RRRRRRRSwSSSSSUUUV VV1WWWWWXXXZ$[.[\q]r] hR@hRh[ h=0J)5 h=0J*5 hzh= h=5 h=0J) h=0J*h=N~PPCQQQ"RSwS+TAUkUU(VV1WWW)XX~YYyZZ#[.[:[[gd[gdAgdzgdzgd[[\\\\r]]k^^_~`` aaa;bbcQckclcrcwcc $Ifgd[gd[$$$d&d1$NPa$gd[gdzgd[gd[gd[r]M_W_aaaaabccQckcccdddddBdadbdddhdiddddddde"e#e$e*e+e-e.e2e3e=e>eyjh| U*hcz7mHnHujh| UhAhhcz7h| B*phh| h:Ijh:IUhR hcz75h[h[5h[h[;CJ hzh[h[ h/(h= h=h=h=h=5h=h ahgL+cccccccUkd$$IfTl\,$$0$44 laytsn T $Ifgd[cccccc\SSSS $Ifgd[kd$$IfTl\,$$0$44 laytsn Tcccccc^UUUU $Ifgd[kd8$$IfTl\,$$0$44 laytsn Tcccccc\SSSS $Ifgd[kd$$IfTl\,$$0$44 laytsn Tcccccc^UUUU $Ifgd[kdp$$IfTl\,$$0$44 laytsn Tcccccc\SSSS $Ifgd[kd $$IfTl\,$$0$44 laytsn Tcccccc^UUUU $Ifgd[kd$$IfTl\,$$0$44 laytsn Tcccccc\SSSS $Ifgd[kdB$$IfTl\,$$0$44 laytsn Tcccccc^UUUU $Ifgd[kd$$IfTl\,$$0$44 laytsn Tcccccc\SSSS $Ifgd[kdz$$IfTl\,$$0$44 laytsn Tcccccc^UUUU $Ifgd[kd$$IfTl\,$$0$44 laytsn Tccdd d d\SSSS $Ifgd[kd$$IfTl\,$$0$44 laytsn T d d d ddd^UUUU $Ifgd[kdP$$IfTl\,$$0$44 laytsn Tdddddddddd\WRRRRRRRgd$ gd[kd$$IfTl\,$$0$44 laytsn T dddddd d!d"d#d$d%d&d'd(d)d*d+d,d-d.d0d1d2d3d4d5d6d7dgd$ 7d8d:d;dd?d@dAdBdCdDdEdFdGdHdIdJdidd $$Ifa$gdG $Ifgd$ gdGgda/5gd$ dddddddTH $$Ifa$gdcz7Kkd$$IfTH0x$`64 HaT $$Ifa$gdG $Ifgd$ Kkd$$IfTH0x$`64 HaTddddddddddddd $$Ifa$gd$ $Ifgd$ gd$ gd$ gdGgda/5KkdF $$IfTH0x$`64 HaT dd eee#eBeZQE $$Ifa$gdG $IfgdWGkd $$IfHU0$ $ $4 Hal $$Ifa$gd$ $Ifgd$ Gkd $$IfHU0$ $ $4 Hal>e@eAeEeFeGehRh:Ih| jh| U*hcz7mHnHu*BeCeDeEeFeGegd[gdGgda/5Gkdg $$IfHU0$ $ &$4 HalE....()()))()000?P&P/R 8$BP/ =!"#8$% Dp$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T$$If!vh#v#v#v#v:V l0$5555ytsn T]$$If!vh#v#v`:V H655`44 HT]$$If!vh#v#v`:V H655`44 HT]$$If!vh#v#v`:V H655`44 HT_$$Ifl!vh#v #v:V HU$5 544 Hal_$$Ifl!vh#v #v:V HU$5 544 Halk$$Ifl!vh#v #v:V HU$,5 5944 Hal+s2 0@P`p2( 0@P`p 0@P`p 0@P`p 0@P`p 0@P`p 0@P`p8XV~ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@ 0@_HmH nH sH tH J`J Normal1$OJQJ\]_HmH sH tH ZZ  Heading 1$ <@&^ ;CJKH \^JaJ RR  Heading 2$ P 1$@&^  5;CJXX  Heading 3$ h!  1$@&^ 5;mH sH DA D Default Paragraph FontVi@V  Table Normal :V 44 la (k (No List P+@P [Endnote Text,EOS$1$a$5;.. TOC 9 ^P@P Footnote Text,Foot Title;X1X  Attachment ID$ !xa$ 5;CJR@2R Header,Head Project  !;4 @B4 Footer  !>O> APRT$$ & F1$a$50Ob0 [TITLE5;:Or: '[PR1$$ & F1$a$TOrT "[ART/$$ & F ``*$1$@&a$;>O> #zPR2$$ & F1$a$\>O> (PR3$$ & F1$a$\>> PR4$$ & F1$a$\>> PR5$$ & F1$a$\|O| &z0CMT $1$5;B*ph>oTjg $(5;OJQJ\]_HmH nH sH tH RR Attachment Name$xa$m$ 5;CJb1b Attachment,Proj Number h!xx^FF Comment xx5;B*CJphHH C , Balloon Text!CJOJQJ^JaJ:/!: [ART Char;OJQJ\]4/14 zPR2 Char OJQJ]DrD =SUT$$*$1$@&a$OJQJ\]DrD =DST%$*$1$@&a$OJQJ\]F/aF z0CMT Char5;B*OJQJ\]ph6/q6 [PR1 CharOJQJ\]4/4 =PR3 Char OJQJ]&o& =SI B*ph&o& =IP B*phPK![Content_Types].xmlN0EH-J@%ǎǢ|ș$زULTB l,3;rØJB+$G]7O٭Vc:E3v@P~Ds |w< G] '194447 3Fr]>eGe378;>AU)*7D~P[cccccccccccc ddd7ddddBeGe4569:<=?@BCDEFGHIJKLMNOPQRSTV!,/7!tt8@0(  B S  ?ptBookmark12968W8H]8H] ssssssssssssM\M\l\l\\\\\\\]H]   U\U\t\t\\\\\] ] ]H]   8 *urn:schemas-microsoft-com:office:smarttagsCity9 *urn:schemas-microsoft-com:office:smarttagsplace=*urn:schemas-microsoft-com:office:smarttags PlaceType=*urn:schemas-microsoft-com:office:smarttags PlaceName   3;s#v#$$$$HQSQCRNR[[\\\$\%\-\.\7\8\A\B\E]H]IP+- 22;;1F2F[[\\\$\%\-\.\7\8\A\B\E]H]33333333t 1^/$S.STYYYZ[\\\\\I\J\d\d\\\\\\\\\\\\\]"]#].]2]A]C]C]D]E]H]t 1^/$S.STYYYZ[\\\\\I\J\J\d\d\\\\\\\\\\\\\\\]"]#].]2]A]C]C]D]E]H](|})S~>B#Ǥʢ4y$*: Kc &r/&H%.X&c}'&Jk3/-ho2ي+#2217t< <&,=qRa@,l@ALk#_ELZdB.L&VTQf=Tsz*F\ `|b&kkn|smJX [oLmszgB {w Qpx:4^`.^`.88^8`.^`. ^`OJQJo( ^`OJQJo( 88^8`OJQJo( ^`OJQJo(hh^h`. hh^h`OJQJo(^`o( PART - ^`o( SCHEDULE  - ^`o(PRODUCT DATA SHEET  - ``^``o(.``^``o(.^`o(.^`o(.  ^ `o()` ` ^` `o()@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.^`.pLp^p`L.@ @ ^@ `.^`.L^`L.^`.^`.PLP^P`L.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.^`o(.^`o(.^`o(.^`o(.ww^w`o(ww^w`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........^`o(.^`o(.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(^`o(.^`o(..^`o(... ^`o( .... ^`o( ..... ^`o( ...... `^``o(....... `^``o(........^`o(.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.^`o(.{^`{o(2.03  ^ `o(..  ^ `o(...   ^ `o( ....   ^ `o( .....   ^ `o( ......  ` ^ ``o(.......  ` ^ ``o(........ww^w`o(ww^w`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........^`o(^`o(.^`o(..^`o(... ^`o( .... ^`o( ..... `^``o( ...... `^``o(....... `^``o(........^`o(.^`o(.{^`{o(3.  ^ `o(..  ^ `o(...   ^ `o( ....   ^ `o( .....   ^ `o( ......  ` ^ ``o(.......  ` ^ ``o(........^`o(.^`o(.^`o(.^`o(^`o(.0^`0o(..0^`0o(... 88^8`o( .... 88^8`o( ..... 88^8`o( ...... `^``o(....... `^``o(........@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.@^`o(.@^`.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L. ww^w`o(hH ww^w`o(hH. 0^`0o(hH. 0^`0o(hH... 88^8`o(hH .... 88^8`o(hH ..... 88^8`o(hH ......  `^``o(hH.......  `^``o(hH........^`o(.@^`o(.^`o(.@pLp^p`L.@@ @ ^@ `.@^`.@L^`L.@^`.@^`.@PLP^P`L.+<<Kc `|b <r/.L#_Ec}'kka@o2VT*F\#2=TB {wH% [o217Epxsm,=4yJk3/msl@A ~}|((&        ي+        &        &         Q        &        &        &h       gf { a` Lw | $ /P/aWMGRsn %B'/(C+F+C ,|/D1s1,5a/5cz7iF.nG9Mv#P*T WTA'YirYW\h+] q_%cv?g5i8[pQtx'g|Of0\ "ZgLOT N]+oPW YK'<pA:II!2jM,T`M0&=L:[yz?&4;>Xl.i3@'MiKQGO2Kz=gw\\@ [[[[G]@UnknownFisher, ShelbyG.[x Times New Roman5Symbol3. .Cx Arial5. .[`)Tahoma7. [ @VerdanaA$BCambria Math"9@)htgtg f TN / TN / $)P4[[2q)PHP ?F+2!xx5q WC:\Documents and Settings\JRCollins\Application Data\Microsoft\Templates\CSI_STYLES.dot Metal LockersFitzgerald,Richard WFitzgerald,Richard W(                           ! " # $ % & ' Oh+'0 0< \ h t Metal LockersFitzgerald,Richard W CSI_STYLESFitzgerald,Richard W2Microsoft Office Word@F#@I@@  TN SZWXXFYDWACR-487-706%b97337ab-eb41-4cf0-a896-e8d4d6ce89f3thttp://fm/groumentManagement.Internal.DocIdHandler/metadata/longProperties"/> ?@ABCDEFGHIJKLMNOPQRSTUVWYZ[\]^_abcdefghijklmnopqrstuvwxyz{|}~Root Entry F@W*_Data X1Table`kWordDocumentGSummaryInformation(DocumentSummaryInformation8,$CompObjrMsoDataStore @'_@'_  !"#$%&'()*+;-./0123456789:A<>?@BCDEF  F Microsoft Word 97-2003 Document MSWordDocWord.Document.89q DocumentLibraryFLOYR5OCIOI==2 @'_@'_Item  x.PropertiesOLKDMSSO0WF==2 @'_@'_Item  Properties DNTROU2APCWQ==2@'_@'_Item PropertiesXXDEJMV55NA==2@'_@'_Item eProperties=value="08"/> This value indicates the number of saves or revisions. The application is responsible for updating this value after each revision. cumentation> This value indicates the number of saves or revisions. The application is responsible for updating this value after each revision. d:element name="contentStatus" minOccurs="0" maxOccurs=ps/cpm/TRG/odgCollaboration/_layouts/15/DocIdRedir.aspx?ID=SZWXXFYDWACR-487-706, SZWXXFYDWACR-487-7062019-03-01T00:00:00Z;#Ready to Publish;# ;#Master;#10 ormDocumentLibraryFormDocumentLibraryForm00Microsof Filter>Document ID Generator Token=71e9bce111e9429cMicrosoft.OfficDocument ID GeneratorSynchronous100011000Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100021001Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100041002Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.DocumentManagement.Internal.DocIdHandlerDocument ID GeneratorSynchronous100061003Microsoft.Office.DocumentManagement, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429cMicrosoft.Office.Docu ՜.+,D՜.+,@ px   " CAPITAL PLANNING AND MANAGEMENT UT MD ANDERSON CANCER CENTER/[ Metal Lockers Title X<p _dlc_DocId_dlc_DocIdItemGuid_dlc_DocIdUrl Published Date to External SiteReady to PublishStatus CSI Division