Building Information Modeling Workflow Documents
The following files provide instructions and support documents for use in the development of BiM/Revit modeling for all MD Anderson
Cancer Center facilities.
MD Anderson Cancer Center does not intend to influence the methods or means of practice of outside consultants. However, it is committed to enforcing the standards of information delivery that insure predictability and the ability to easily reuse information. As a result, these standards will be included as part
of the contractual requirements for delivery of electronic information.
We recognize that there will be times when deviations from these standards may be appropriate on some projects, and in those instances, the design professional is expected to notify the Owner's Project Manager in writing for approval to deviate.
If you have any comments/questions/suggestions about the information included within the MD Anderson Building Information Modeling Requirements, please contact Kelly Robichau by email.
Note: The Building Information Modeling Requirements are best viewed in Google Chrome or Microsoft Edge.
Building Information Modeling Standards | Instructions | Published Date |
MDA Revit Equipment Asset Tracking Procedure V1.3 | Step-by Step Procedure for Picklist & Dynamo Script Process | 20231128 |
MDA_Revit Maximo Data Picklist | Refer to Step 7 per V1.2 process | 20231010 |
MDA_Revit Maximo Data Baseline | Indicates the assets that are required to be modeled by the Design team AOR & EOR, which are highlighted in yellow. These assets are to be implemented in the MDA Revit Equipment Asset Tracking Procedure. The items highlighted in green are to be reviewed by project, subject to be required to be modeled. | 20250109 |
MDA_Valve Matrix | Valve Matrix to provide clarification to project teams which valves are to be modeled, mapped with CMMS data and asset tagged. Note where item(s) are required to be modeled, these should be in the Design Models and tracked through as per Model Lifecycle Diagram.¡± |
20250204 |
MDA_Revit Maximo Data Transfer File | Refer to Step 11, #8 per V1.3 process. (This is the excel file that is getting populated from models.) | 20250331 |
MDA_Revit Warehouse Model_R23 | Refer to Step 2 per V1.3 process. | 20241213 |
MDA Revit Space Naming Procedure V1.0 |
Refer to this documentfor the creation of Spaces in design models. | 20241213 |
MDA Revit Equipment Asset Number Import Procedure V1.0 |
Refer to this document when importing MDA provided Asset Numbers back into design models | 20241213 |
MDA_Revit Maximo Data Export_Architecture | Dynamo Script to run from Architectural model(s); Refer to Step 11 per V1.3 process | 20241220 |
MDA_Revit Maximo Data Export_MEP | Dynamo Script to run from MEP model(s); Refer to Step 11 per V1.3 process | 20241220 |
Note: Operations and Maintenace has developed worksheets with specific data they want for AHUs, PUMPs and FANs.To support this effort, we are asking for AHUs, PUMPs and FANs, for Step 11 to use the following scripts, respectively.
|
||
MDA_Revit Maximo Data Export_PUMP.dyn | Refer to Step 11 per V1.3 process | 20241220 |
MDA_Revit Maximo Data Export_AHU.dyn | Refer to Step 11 per V1.3 process | 20241220 |
MDA_Revit Maximo Data Export_FAN.dyn | Refer to Step 11 per V1.3 process | 20241220 |
MDA Revit Maximo Data Import ASSET NUMBER.dyn |
Dynamo Script to run via instructions provided by the MDA Revit Equipment Asset Number Import Procedure document | 20241213 |
request an appointment online.