HVAC Control Document Requirements
All HVAC controls specified within contract documents shall comply with MD Anderson Cancer Center standards.
The following instructions and drawing templates are provided for consultants use in developing control drawings for MD Anderson Cancer Center projects.
Note: The HVAC Control Document Requirements are best viewed in Google Chrome or Microsoft Edge.
To view or print the .dwg files contained within the below HVAC Control Documents Library, you will need to use Google Chrome or Microsoft Edge as your browser.
PLEASE READ THIS UPDATE BEFORE DOWNLOADING ANY OF THESE DOCUMENT FROM THIS WEBSITE
The MD Anderson ODGs have added updated control drawing templates which incorporate ASHRAE Guideline 36 - 2021 where applicable. All control drawings named with the prefix ¡°MDA_ODG¡± are the current control drawing standard. Engineers should use these control drawings as guidelines to develop control drawings for applicable systems on their projects. These posted control drawings supersede all other control drawings on this website.
These control drawings are only available in PDF format on this website. If these are needed for your assigned project, please request your MD Anderson Project Manager to contact Building Operation Technologies (c/o Victor Juel) for access to the configurable Revit (.rvt) files via a OneDrive folder invitation.
- MDA_ODG -G000 - COVER PAGE
- MDA_ODG -ICc001 - INSTRUMENTATION SYMBOLS & ABBREVIATIONS
- MDA_ODG -ICc002 - NETWORK ARCHITECTURE DIAGRAM
- MDA_ODG -ICc003 - OPTIMIZATION SUPERVISOR
- MDA_ODG -ICc010 - PLANT - CHILLED WATER TECO HEAT EXCHANGERS
- MDA_ODG -ICc011 - PLANT - HOT WATER TECO HEAT EXCHANGERS
- MDA_ODG -ICc012 - PLANT - CHILLED WATER SYSTEM WITH AIR COOLED CHILLERS
- MDA_ODG -ICc013 - PLANT - HEATING HOT WATER SYSTEM WITH BOILERS
- MDA_ODG -ICc014 - PLANT - HEAT RECOVERY CHILLER SYSTEM
- MDA_ODG -ICc020 - AIR SYSTEM - AIR HANDLING UNIT - MULTI-ZONE
- MDA_ODG -ICc021 - AIR SYSTEM - AIR HANDLING UNIT - SINGLE-ZONE
- MDA_ODG -ICc022 - AIR SYSTEM - ENERGY RECOVERY UNIT
- MDA_ODG -ICc023 - AIR SYSTEM - ENERGY RECOVERY UNIT
- MDA_ODG -ICc024 - AIR SYSTEM - OUTSIDE AIR HANDLING UNIT
- MDA_ODG -ICc025 - AIR SYSTEM - OUTSIDE AIR HANDLING UNIT
- MDA_ODG -ICc030 - AIR SYSTEM - GENERAL EXHAUST
- MDA_ODG -ICc031 - AIR SYSTEM - LAB MANIFOLD EXHAUST
- MDA_ODG -ICc032 - AIR SYSTEM - STAIRWELL PRESSURIZATION FAN
- MDA_ODG -ICc040 - ZONE - FAN COIL UNIT WITH REHEAT
- MDA_ODG -ICc041 - ZONE - VARIABLE AIR VOLUME WITH REHEAT
- MDA_ODG -ICc042 - ZONE - VARIABLE AIR VOLUME - DUAL DUCT
- MDA_ODG -ICc043 - ZONE - SERIES FAN POWERED BOX - CONSTANT VOLUME
- MDA_ODG -ICc044 - ZONE - SERIES FAN POWERED BOX - VARIABLE VOLUME
- MDA_ODG -ICc045 - ZONE - VARIABLE AIR VOLUME WITH REHEAT - TRACKING PAIR
- MDA_ODG -ICc050 - ZONE - VENTURI AIR VALVE PRESSURE CONTROL - LAB WITH HOOD & POINT EXHAUST
- MDA_ODG -ICc051 - ZONE - BLADE DAMPER AIR VALVE PRESSURE CONTROL - LAB WITH HOOD & POINT EXHAUST
- MDA_ODG -ICc060 - MISCELLANEOUS CONTROL AND MONITORING POINTS
HVAC Control Document Library
This site permits downloading zipped AutoCAD drawing files of HVAC control drawing templates for consultants use in developing contract construction documents for MD Anderson Cancer Center projects.
The consultant may utilize these template drawings or create new drawings provided that they are formatted as demonstrated by the templates. The consultant shall review and modify any drawing downloaded to comply with all applicable specifications and design guidelines, and customize the template to fit the application for their project.
These drawings are intended for use only in connection with work performed for MD Anderson Cancer Center and shall not be used for any other purpose without the written consent from the Owner.
- Examples of Design & Control Strategy Supported by MD Anderson
- Application Specific Controller Control Identification Matrix
- Mechanical Equipment Control Library Identification Matrix
- Specialty Equipment Control Library Identification Matrix
- Air Handler Unit Control Library Identification Matrix
Important: All Control Contract Drawings shall comply with the following requirements:
Instructions for the Preparation of Control Contract Documents
Examples of Design & Control Strategy Supported by MD Anderson
Sheet I.D. | Sheet Title | Posted Date |
APGLE4FS | General Lab Exhaust (4-Pack) Fan System | 03/15/12 |
APSPF1PC | Stairwell Pressurization Fan (SPF) System ( For Patient Care & Admin Bldgs. ) |
12/20/12 |
APSPF2RE |
Stairwell Pressurization Fan (SPF) System | 12/20/12 |
APOAFA | OAHU With Fan Array System | 05/09/13 |
Application Specific Controller Control Drawing Templates
Sheet I.D. | Sheet Title | Posted Date |
ETCUXD14 | CV Dual Duct with 2 Inlet Sensors | 08/01/07 |
ERCE2CNR | CV Room Pressurization with HW Reheat | Pending |
ETCXAD10 | CV with Hot Water Reheat | 08/01/07 |
ETCXXD01 | CV Cooling Only | 08/01/07 |
ETCXXD02 | CV Cooling Only (No Space Sensor) | 08/01/07 |
ETGXXD01 | Fan Coil Unit 2 Pipe HW/CHW | 08/01/07 |
ETGXXD02 | Fan Coil Unit CHW Cooling and HW Heating | 08/01/07 |
ETGXXD03 | Fan Coil Unit 2-Stage Cooling and Hot Water Heat | 08/01/07 |
ETGXXD05 | Fan Coil Unit 2-Stage Cooling and Electric Heat | 08/01/07 |
ETGXXD06 | Fan Coil Unit CHW Cooling and Electric Heat | 08/01/07 |
ETRXXD01 | Hot Water Reheat Only | 08/01/07 |
ETVUXD04 | VAV Dual Duct with 2 Inlet Sensor | 08/01/07 |
ETVSXD03 | VAV Series Fan Powered with Electric Reheat | 08/01/07 |
ETVSXD11 | VAV Series Fan Powered with Hot Water Reheat | 01/09/12 |
ERVP2VNR | VAV Room Pressurization with Hot Water Reheat | Pending |
ETVIXD01 | VAV Cooling Only | 08/01/07 |
ETVIXD08 | VAV with Electric Reheat | 08/01/07 |
ETVIXD18 | VAV with Hot Water Reheat | 01/09/12 |
ETVIXD26 | VAV with Hot Water Reheat and Humidity Control | 08/01/07 |
ETHXXD02 | Unit Heater for Mechanical Rooms | 08/01/07 |
DPM05 | Differential Pressure Monitor 1 Pressure Transmitter | 08/01/07 |
DPM06 | Differential Pressure Monitor 2 Pressure Transmitter | 08/01/07 |
Mechanical Equipment Control Drawing Templates
Sheet I.D. | Sheet Title | Posted Date |
EH1S | One (1) Boiler | Pending |
EH1B1D | One (1) Boiler w/ Dedicated Pump | 08/01/07 |
EH1B2H | One (1) Boiler w/ Two Pumps (One Standby) & Mixing Valve | Pending |
EH1B1H | One (1) Boiler w/ Headered Pump & Mixing Valve | Pending |
EH2S | Two (2) Boilers Pending | Pending |
EH2B2D | Two (2) Boilers w/ Dedicated Pumps | Pending |
EH2B2H | Two (2) Boilers w/ Headered Pumps & Mixing Valve | 08/01/07 |
EH3S | Three (3) Boilers |
Pending |
EH3B3D | Three (3) Boilers w/ Dedicated Pumps | Pending |
EH3B3H | Three (3) Boilers w/ Headered Pumps & Mixing Valve | Pending |
EC1R2H | One (1) Air Cooled Reciprocating Chiller w/ 2 Pumps | Pending |
EC1C1D | One (1) Chiller w/ Dedicated Pump | Pending |
EC1C2H | One (1) Chiller w/ Headered Pump | Pending |
EC2C2D | Two (2) Chillers Basic Control | Pending |
EC2C2H | Two (2) Chillers w/ Headered Pumps | Pending |
EC3C3D | Three (3) Chillers w/ Dedicated Pumps | Pending |
EC3C3H | Three (3) Chillers w/ Headered Pumps | 08/01/07 |
EC1Z2C | Two (2) CHW Constant Volume Pumps | 08/01/07 |
EC1Z2B | Two (2) CHW Constant Volume Pumps w/ Bypass Valve | 08/01/07 |
EC1Z2V | Two (2) CHW Variable Speed Pumps | 08/01/07 |
EC1T1V | One (1) Cooling Tower, Variable Speed | Pending |
EC1T1M | One (1) Cooling Tower, Multi Speed | Pending |
EC1T1S | One (1) Cooling Tower, Single Speed | Pending |
EC2T1V | Two (2) Cooling Towers, Variable Speed | Pending |
EC2T1M | Two (2) Cooling Towers, Multi Speed | Pending |
EC2T1S | Two (2) Cooling Towers, Single Speed | Pending |
EC3T1V | Three (3) Cooling Towers, Variable Speed | Pending |
EC3T1M | Three (3) Cooling Towers, Multi Speed | Pending |
EC3T1S | Three (3) Cooling Towers, Single Speed | Pending |
EH1X2H2 | Steam to HW Converter w/ 1/3-2/3 Valve | Pending |
EH1X2H1 | Steam to HW Converter w/ Single Valve | 08/01/07 |
EH1Z2C | Two (2) HW Constant Volume Pumps | 08/01/07 |
EH1Z2B | Two (2) HW Variable Speed Pumps | 08/01/07 |
EH1Z2V | Two (2) HW Variable Speed Pumps |
08/01/07 |
EXFAN1 | General Exhaust Fans Four (4) different types | 08/01/07 |
EXFAN2 | General Exhaust Fans w/ Temperature Control - Four (4) different types | 08/01/07 |
Specialty Equipment Control Drawing Templates
Sheet I.D. | Sheet Title | Posted Date |
Fan Wall | Fan Wall Unit | 01/09/12 |
LLEB1-01 | Siemens Lab Controller with Hood Exhaust | 08/01/07 |
LLEB1-02 | Phoenix Lab Controller with Hood Exhaust | 11/21/19 |
LLEB1-11 | Siemens Lab Controller with Hood & General Exhaust | 08/01/07 |
LLEB1-12 | Phoenix Lab Controller with Hood & General Exhaust | 11/21/19 |
LLEB1-21 | Phoenix Lab Controller without Hood | 11/21/19 |
Air Handler Unit Control Drawing Templates
Legend | |||
1. Single Duct | 7. With 1 Return Fan | 13. Preheat Coil | 19. Cooling Coil |
2. Dual Duct | 8. With 2 Return Fans | 14. Preheat Electric | 20. DX Coil |
3. OA / Return Air | 9. CV Supply Fan | 15. Precool Coil | 21.Heat Recovery Wheel |
4. Return Air Only | 10. VAV 1 Supply Fan - VFD | 16. Face & Bypass Damper | 22. Reheat Coil |
5. Without Freeze Protection | 11.VAV 2 Supply Fans - VFD | 17. Heating Coil | 23. Reheat Electric |
6. 100% OA | 12. With Air Flow Monitor | 18. Heating Electric | 24. With Humidifier |
Sheet I.D. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | Posted Date |
|
|
|
X |
|
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
|
|
08/01/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
|
X |
|
08/01/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
08/01/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
08/01/07 |
|
X |
|
X |
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
|
X |
|
08/01/07 |
|
X |
|
X |
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
08/01/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
11/05/07 |
|
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
X |
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
|
11/05/07 |
|
X |
|
X |
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
X |
11/05/07 |
|
X |
|
X |
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
|
11/05/07 |
|
X |
|
X |
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
|
|
|
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
X |
|
X |
|
|
|
|
X |
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
X |
|
X |
|
|
|
|
|
11/05/07 |
|
X |
|
X |
|
|
|
|
|
X |
|
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
11/05/07 |
|
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
11/05/07 |
|
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
11/05/07 |
|
X |
|
|
|
X |
X |
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
11/05/07 |
|
X |
|
|
|
X |
X |
|
|
|
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
11/05/07 |
|
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
X |
11/05/07 |
|
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
|
11/05/07 |
|
X |
|
|
|
X |
X |
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
X |
11/05/07 |
|
EACVODLN |
X |
|
|
|
X |
X |
|
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
|
Pending |
EACVOFCH |
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
Pending |
EACVOFCN |
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
|
|
|
Pending |
EACVOFNN |
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
Pending |
EACVOHCH |
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
X |
X |
|
|
|
|
X |
Pending |
EACVOHCN |
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
X |
X |
|
|
|
|
|
Pending |
EACVOHNN |
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
|
Pending |
EACVOKCN |
X |
|
|
|
X |
X |
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EACVONCN |
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EACVOP2H |
|
X |
|
|
|
X |
|
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
X |
Pending |
EACVOQ2H |
|
X |
|
|
X |
X |
|
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
X |
Pending |
EACVOQFH |
X |
|
|
|
X |
X |
|
|
X |
|
|
|
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
Pending |
EACVOQFN |
X |
|
|
|
X |
X |
|
|
X |
|
|
|
X |
|
X |
|
|
|
X |
|
|
X |
|
|
Pending |
EACVRCHH |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EACVRCHN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EACVRCLH |
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EACVRCLN |
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EACVRDHH |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
X |
Pending |
EACVRDHN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
|
Pending |
EACVRDLH |
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
X |
Pending |
EACVRDLN |
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
X |
|
|
Pending |
EACVRDNN |
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
Pending |
EACVRFCH |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
Pending |
EACVRFCN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
|
|
|
Pending |
EACVRFNN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
Pending |
EACVRHCH |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
X |
|
X |
|
|
|
|
X |
Pending |
EACVRHCN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
X |
|
X |
|
|
|
|
|
Pending |
EACVRHNN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
Pending |
EACVRKCN |
X |
|
X |
|
X |
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EACVRNCN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EACVRWHN |
X |
|
X |
|
|
|
X |
|
X |
|
|
|
|
|
|
|
|
|
|
|
X |
X |
|
|
Pending |
EAVARCHH |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
|
|
|
X |
|
X |
Pending |
EAVARCHN |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EAVARCLH |
X |
|
X |
|
X |
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EAVARCLN |
X |
|
X |
|
X |
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EAVARFCH |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
X |
|
|
X |
|
|
X |
|
X |
Pending |
EAVARFCN |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
X |
|
|
X |
|
|
|
|
|
Pending |
EAVARHCH |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
|
X |
X |
|
|
|
|
X |
Pending |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
|
X |
X |
|
|
|
|
|
08/01/07 |
|
EAVARKCH |
X |
|
X |
|
X |
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
X |
Pending |
EAVARKCN |
X |
|
X |
|
X |
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EAVARN2N |
|
X |
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
X |
|
X |
|
|
|
|
|
Pending |
EAVARNCH |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
X |
Pending |
EAVARNCN |
X |
|
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
|
X |
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
X |
|
X |
|
|
|
|
X |
08/01/07 |
|
EAVARP2N |
|
X |
X |
|
|
|
X |
|
|
X |
|
X |
|
|
|
|
X |
|
X |
|
|
|
|
|
Pending |
EAVSMCHH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EAVSMCHN |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EAVSMCLH |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EAVSMCLN |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EAVSMFCH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
Pending |
EAVSMFCN |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
X |
|
|
X |
|
|
|
|
|
Pending |
EAVSMHCH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EAVSMHCN |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EAVSMKCH |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EAVSMKCN |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
X |
Pending |
EAVSMNCH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
X |
Pending |
EAVSMNCN |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EAVSOCHH |
X |
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EAVSOCHN |
X |
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EAVSOFCH |
X |
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
Pending |
EAVSOFCN |
X |
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
X |
|
|
X |
|
|
|
|
|
Pending |
EAVSOHCH |
X |
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
|
X |
|
X |
|
|
|
|
X |
Pending |
X |
|
|
|
|
X |
|
|
|
X |
|
|
|
|
|
|
X |
|
X |
|
|
|
|
|
08/01/07 |
|
EAVSOKCN |
X |
|
|
|
X |
X |
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
|
X |
|
|
|
X |
|
|
|
X |
|
|
X |
|
X |
|
X |
|
X |
|
|
|
|
X |
08/01/07 |
|
EAVSOQ2H |
|
X |
|
|
X |
X |
|
|
|
X |
|
|
X |
|
X |
|
X |
|
X |
|
|
|
|
X |
Pending |
EAVSRCHH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
08/01/07 |
|
EAVSRCLH |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
X |
Pending |
EAVSRCLN |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
X |
|
|
Pending |
EAVSRFCH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
Pending |
EAVSRFCN |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
X |
|
|
X |
|
|
|
|
|
Pending |
EAVSRHCH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
X |
|
X |
|
|
|
|
X |
Pending |
EAVSRHCN |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
X |
|
X |
|
|
|
|
|
Pending |
EAVSRKCH |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
X |
Pending |
EAVSRKCN |
X |
|
X |
|
X |
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EAVSRNCH |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
X |
Pending |
EAVSRNCN |
X |
|
X |
|
|
|
|
|
|
X |
|
|
|
|
|
|
|
|
X |
|
|
|
|
|
Pending |
EDVARFCH |
X |
|
X |
|
|
|
|
X |
|
|
X |
X |
|
|
|
X |
|
|
X |
|
|
|
|
X |
Pending |
EDVSRFCH |
X |
|
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
Pending |
EDVSRFCN |
X |
|
X |
|
|
|
|
X |
|
|
X |
|
|
|
|
X |
|
|
X |
|
|
X |
|
|
Pending |
request an appointment online.
Help #EndCancer
Give Now
Donate Blood
Our patients depend on blood and platelet donations.